User manual / Handbuch / Návod k obsluze
KEA 2
LL Lenght (loop-loop)
Wire length
1) Before checking the wire length, pre-tension the line by the load of 22 kilograms for about
3 seconds per each line.
2) Always measure the wire length only when the line is tensioned by 5 kilograms.
3) If you need to cut the new line, the line has to be stabilized by the tension of 22 kilograms
and only then could be cut under the tension of 5 kilograms.
LINE SPECIFICATIONS |
KEA 2 S
NAME
QUANTITY MATERIAL
LL LENGTH WIRE LENGTH
Certification glider
A1
2
Top line 16175
183,2
656,9
655,9
A2
2
Top line 16175
175,8
649,5
648,4
A3
2
Top line 16175
178,9
652,6
651,3
AU1
2
Vectraline 12470
474,5
reinforced
A4
2
Top line 16175
181,5
649,9
648,7
A5
2
Top line 16175
174,7
643,1
641,8
A6
2
Top line 16175
178,3
646,7
645,3
AU2
2
Vectraline 12470
469,2
reinforced
A7
2
Top line 16175
133,1
645,7
644,7
A8
2
Top line 16175
124,9
637,5
636,5
A9
2
Top line 16175
120,2
632,8
631,8
A10
2
Top line 16175
117,6
630,2
628,9
AO
4
Top line 16175
122,7
reinforced both sides
AU3
2
Vectraline 16330
391,0
B1
2
Top line 16175
183,1
649,7
648,6
B2
2
Top line 16175
175,8
642,4
641,4
B3
2
Top line 16175
178,8
645,4
644,1
BU1
2
Vectraline 12470
467,4
reinforced
B4
2
Top line 16175
181,0
642,9
641,6
B5
2
Top line 16175
174,6
636,5
635,0
B6
2
Top line 16175
178,6
640,5
639,0
BU2
2
Vectraline 12470
462,7
reinforced
B7
2
Top line 16175
130,5
640,7
639,2
B8
2
Top line 16175
124,0
634,2
632,7
B9
2
Top line 16175
121,1
631,3
629,5
B10
2
Top line 16175
119,5
629,7
628,0
BO
4
Top line 16175
122,7
reinforced both sides
BU3
2
Vectraline 16330
388,6
NAME
QUANTITY MATERIAL
LL LENGTH WIRE LENGTH
Certification glider
C1
2
Top line 16175
173,5
651,9
650,6
C2
2
Top line 16175
165,7
644,1
642,8
C3
2
Top line 16175
169,3
647,7
646,4
CU1
2
Vectraline 16330
479,0
reinforced
C4
2
Top line 16175
171,4
645,2
644,0
C5
2
Top line 16175
164,6
638,4
637,3
C6
2
Top line 16175
169,2
643,0
641,6
CU2
2
Vectraline 16330
474,4
reinforced
C7
2
Top line 16175
124,6
647,6
646,2
D7
2
Top line 16175
126,5
649,5
648,0
C8
2
Top line 16175
117,4
640,4
639,0
C9
2
Top line 16175
114,0
637,0
635,5
D8
2
Top line 16175
116,4
639,4
638,0
C10
2
Top line 16175
112,0
635,0
633,4
CO
4
Top line 16175
115,8
reinforced both sides
CU3
2
Vectraline 16330
408,3
D1
2
Top line 16175
163,6
662,5
661,2
D2
2
Top line 16175
155,6
654,5
653,2
D3
2
Top line 16175
160,1
659,0
657,7
DU1
2
Vectraline 16330
499,5
reinforced
D4
2
Top line 16175
161,9
656,7
655,4
D5
2
Top line 16175
154,6
649,4
647,8
D6
2
Top line 16175
159,7
654,5
653,0
DU2
2
Vectraline 16330
495,4
reinforced
NAME
QUANTITY MATERIAL
LL LENGTH WIRE LENGTH
Certification glider
A11
2
Top line 16175
111,1
610,5
609,5
A12
2
Top line 16175
100,5
599,9
598,7
B11
2
Top line 16175
108,9
608,3
607,2
C11
2
Top line 16175
114,4
613,8
612,7
SA
2
Top line 16175
90,6
590,0
588,6
SB
2
Top line 16175
90,2
589,6
588,3
SC
2
Top line 16175
95,7
595,1
593,7
SO
4
Top line 16175
146,8
reinforced both sides
SU
2
Vectraline 16330
353,7
F1
2
Top line 16175
178,2
734,7
736,8
F2
2
Top line 16175
156,9
713,4
715,3
F3
2
Top line 16175
142,4
698,9
700,3
F4
2
Top line 16175
135,0
691,5
693,1
F5
2
Top line 16175
126,2
682,7
684,4
F6
2
Top line 16175
114,9
671,4
673,2
F7
2
Top line 16175
110,9
667,4
669,2
F8
2
Top line 16175
113,3
669,8
671,6
F9
2
Top line 16175
107,1
663,6
665,2
F10
2
Top line 16175
102,2
658,7
660,3
F11
2
Top line 16175
97,0
653,5
655,0
F12
2
Top line 16175
92,1
648,6
650,3
FOO
12
Top line 16175
112,3
FOU
6
7850-080-040
224,0
FU
2
7850-200-040
223,8
Measurements done according to the EN standard 926-2 |2013 (measured under a tension of 50N)
Tolerance: +/- 1 cm
30
Summary of Contents for KEA 2 L