SPG 84 Installation manual
7.
Outputs:
•
Output:
There are 4 outputs freely programmable by functions.
•
Name:
You may enter any description to this zone.
Factory default: Empty
•
Type:
Output types could be selected here,
−
Disabled:
This output is disabled. It can not be activated from
anywhere.
−
Armed:
Will follow the Armed status of the SPG 84
−
Disarmed:
Will follow the Disarmed status of the SPG 84
−
Alarm:
Will follow the Alarm status of the SPG 84
−
24h Alarm
Will follow any 24h Alarm zone status.
−
Technical
Will follow any Technical zone status
−
Tamper
:
Will follow any Tamper status of the SPG84
−
Entry/Exit:
Will follow the exit entry time status of the SPG .
−
Communication Fail:
Will be activated if there is a communication failure between the SPG 1000 and the SPG 84
−
Zone Follower:
Will follow status of any zone selected
−
Server control:
If SPG 84 receives a SMS command either from SMS or directly form SPG 1000 programming web.
−
AC Loss:
Will be activated if AC loss input is activated.
−
AC LOSS TIME OUT:
Will be acivated if AC LOSS timeout is expired, and still no AC power.
−
LOW Battery:
This information is from SPG 1000 only. If DC power drops under DC 11,8 V it will be activated.
Factory Default : All disabled
•
Mode:
Setting the timing of the output
−
Monostable:
Will follow the event with the timing as event occures.
−
Bistable:
Two state output. The output will be activated by the event, and will stay in that as timing is set.
Factory default: Monostable