For standard maintenance of
Model 86
, follow these instructions:
Shut off the water supply and drain the unit by removing the threaded
plug in the bottom of the humidifier.
Remove the drum and disassemble the unit by reversing the final
assembly instructions for
Model 86
on page 12.
Remove the evaporator pad from the drum by squeezing the finger
prongs on the clip, holding the drum end in place and pulling. (See
Figure 19, page 20.)
Clean all non-electrical parts with humidifier cleaner or a 50/50 solution
of vinegar and water. Rinse all parts thoroughly with fresh water before
putting the unit back into operation.
Discard the water in the water pan and remove mineral deposits from
the bottom of the pan. Clean mineral deposits from around the water
valve. When reversing or replacing the rubber valve seat, be sure
the rubber is facing the valve jet opening. Turn the adjustment screw
clockwise (
) to lower, or turn it counterclockwise (
) to increase the
water level.