How to Install a Skuttle
Model 60-Series Steam Humidifier
NOTES: This humidifier must be installed by a qualified professional
contractor. Failure to comply with this requirement may nullify the
warranty.
Read all instructions before beginning installation of the humidifier.
Skuttle Manufacturing Company assumes no responsibility under
warranty if the contractor and user do not follow these printed
instructions.
FOR INSTALLATION OF THE HUMIDISTAT, PLEASE SEE SEPARATE
INSTRUCTIONS ENCLOSED IN THE HUMIDIFIER CARTON.
Safety Precautions
1.
Do not install a humidifier where the surrounding temperatures may
exceed 200°F.
CAUTION:
Excessive heat will damage the humidifier, possibly
causing an overflow condition and water damage to the home.
2.
Do not install a humidifier where the surrounding temperature may be
32°F or colder (e.g., attics, garages, etc.).
CAUTION:
Freezing water will damage the humidifier and burst the
supply pipe, resulting in damage to the home.
3.
Do not cut or drill into any air conditioning or electrical accessories
during humidifier installation.
DANGER: Electrocution is possible if you come in contact with
a live electrical wire; blindness can occur if Freon contacts your
eyes.
4.
When the humidifier is installed in a finished basement or any area
where water damage could occur, be sure to connect the humidifier's
overflow provision to a suitable drain.
5.
For above-ceiling installations, install an additional drain pan
plumbed to a suitable drain.
6.
Installation, wiring and plumbing of the humidifier must comply with
local codes, ordinances and regulations.