background image

 

  

                                                                                                    

 

 

~ 8 ~

 

 

3.  Programming 

 

 

3.1 Programming Only One Call Address (One Call Button for One Intercom Unit) 
 

Set the desired call address for the device on the DIP-Switch following the SKS-BUS Address Table in 
the  appendix.  Each  call  address  is  assigned  to  one  call  button  in  the  door  station.  The  call  address 
distribution is stored in the door station or in the door speaker 4503, 4508 or 4808. 

 
 

3.2

 

Programming up to 4 Call Addresses  

(2...4  Call buttons for an Intercom Unit or Internal Call Units) 

 

The  intercom  unit  can  store  up  to 4  SKS-BUS  call  addresses  for  house  call,  internal  call  or  group  call 
addresses.  The  first  address  is  the  main  address  and  is  transmitted  as  the  device  identification.  The 
intercom unit  will respond  to up to 3  additional call addresses for incoming house calls (call button for 
the  door  station),  internal  calls  (talking  between  two  intercom  units)  and  group  calls  (talking  between 
one intercom unit and up to 4 other intercom units).   

 

Note: 

With intercom unit that can mute the ringer, the ringer must be turned on during programming.   

 

Step  

Description 

Set the call address on the DIP-Switch. The 1st call address is the house call 
(call button on the door station).  

Push the programming button for about 5 seconds until you hear the control 
tone.  

After this control tone sounds you will hear a short tone that signals that the 
first call address has been programmed. The number of short tones indicates 
the memory location at which the call address was stored.   

To program additional call addresses, repeat steps 1 to 3. A maximum of 4 call 
addresses can be stored. If call addresses need to be changed, all call 
addresses must first be deleted, as described under 3.3. 

 

Note: 

After programming is finished, set the DIP-Switch to the main address again so that it is possible 
o to assign the button to the intercom in the case of a fault.  

 
 
3.3 Delete All Call Addresses 
 

Call  addresses  can  not  be  deleted  individually.  All  addresses  are  deleted  every  time.  Hold  the 
programming button down for around 25 seconds. While you are doing this, you will hear several control 
tones. Deletion is completed when you hear a 3-second-long high-pitched signal tone. Now release the 
programming button. All call addresses have been deleted.   

 

Note: 

After you have deleted the programmed call addresses, only the address set on the DIP-Switch 
is in effect, as described under 3.1.  

  

  

For special function 

only 

DIP switch  

programming key 

Summary of Contents for HT 4500

Page 1: ... 1 HT 4500 Version 1 2 ...

Page 2: ...lteten Leitungen gegen irrtümliches Wiedereinschalten Stellen Sie Spannungsfreiheit durch Messung fest Decken Sie benachbarte unter Spannung stehende oder leitfähige Teile ab Alle Arbeiten und elektrische Anschlüsse müssen den nationalen Bestimmungen des jeweiligen Landes entsprechen und von entsprechend ausgebildetem Fachpersonal durchgeführt werden Bei Geräten mit 230 V Anschluss ist die DIN VDE...

Page 3: ... Schalter einstellen Die 1 Rufadresse ist der Hausruf Klingeltaste an der Türstation 2 Die Programmiertaste für ca 5 Sekunden drücken bis der erste Kontrollton ertönt 3 Nach diesem Kontrollton ertönt ein kurzer Ton Er signalisiert dass die erste Rufadresse programmiert ist Die Anzahl der kurzen Töne signalisieren auf welchem Speicherplatz die Rufadresse gespeichert wurde 4 Zum Programmieren weiter...

Page 4: ...Tontaste gedrückt halten und anschließend die Türöffnertaste innerhalb von 2 Sekunden kurz drücken Mit jedem Tastendruck der Türöffnertaste erklingt eine andere Melodie Wird die gewünschte Melodie abgespielt lassen Sie beide Tasten los Es stehen 8 verschiedene Kingeltöne zur Auswahl Etagenrufklingelton ändern Die Tontaste gedrückt halten und anschließend die Türöffnertaste innerhalb von 2 Sekunden...

Page 5: ...he Daten Elektrische Daten Spannung a b 19 23VDC Allgemeines Umgebungstemperatur 10 C bis 45 C Feuchtigkeit 20 bis 90 nicht kondensierend Gehäuse Kunststoffgehäuse Abmessungen Breite x Höhe x Tiefe 89 x 230 x 58 mm ...

Page 6: ... 6 ...

Page 7: ...nected lines against erreneous reconnection Use a measuring device to make sure that the wires are deenergized Cover up any adjacent energized or conducting components All work and all electrical connections must comply with the national provisions for the country in question and must be performed by appropriately trained personnel DIN VDE 0100 must be observed and complied with in devices with a ...

Page 8: ...st call address is the house call call button on the door station 2 Push the programming button for about 5 seconds until you hear the control tone 3 After this control tone sounds you will hear a short tone that signals that the first call address has been programmed The number of short tones indicates the memory location at which the call address was stored 4 To program additional call addresses...

Page 9: ...ush the open door button within 2 seconds A different tune will sound with each push of the button When the desired tune plays release both buttons 8 different buttons are available Change floor call tune Push the sound button and then quickly push the open door button within 2 seconds A different tune will sound with each push of the button Wait until the desired tune plays then release both butt...

Page 10: ...0 5 Technical Data Electrical Data Voltage a b 19 23VDC General Ambient temperature 10 C to 45 C Humidity 20 to 90 non condensing Housing Plastic housing Dimensions width x height x depth 89 x 230 x 58mm ...

Page 11: ... 11 ...

Page 12: ...onnectées de manière à empêcher toute remise sous tension accidentelle Constatez l absence de tension en procédant à une mesure Recouvrez les éléments voisins sous tension ou conducteurs Tous les travaux et les connexions électriques doivent répondre aux dispositions nationales du pays concerné et sont l affaire de spécialistes dûment qualifiés La norme DIN VDE 0100 est à observer et à respecter p...

Page 13: ...pel extérieur touche de sonnerie sur la station de porte 2 Appuyer environ 5 secondes sur le bouton de programmation jusqu à ce que la tonalité de contrôle retentisse 3 Après cette tonalité de contrôle une brève tonalité signale que la première adresse d appel est programmée Le nombre de brèves tonalités signale sur quel emplacement de mémoire l adresse d appel a été enregistrée 4 Répétez les étap...

Page 14: ...ez enfoncée la touche son puis appuyez brièvement pendant 2 secondes la gâche d ouverture de porte Une sonnerie différente retentit à chaque pression de touche Une fois la mélodie souhaitée exécutée relâchez les deux touches On peut choisir entre 8 tonalités de sonneries Changer la tonalité d appel à l étage Maintenez appuyée la touche son puis pressez brièvement pendant 2 secondes la gâche d ouve...

Page 15: ...echniques Caractéristiques électriques Tension a b 19 23VDC Généralités Température ambiante de 10 C à 45 C Humidité 20 à 90 sans condensation Boîtier Boîtier plastique Dimensions largeur x hauteur x profondeur 89 x 230 x 58mm ...

Page 16: ... 16 ...

Page 17: ... 17 Anhang Appendix Annexe DIP Switch settings for intercoms switch actuator and TK Adapter Standard address range Extended address range ...

Reviews: