28
Technical manual
DOL 278AT
13.5 Connection to the Climate Computer
1)
Remove the jumper plug (
A
) (place it in the cabinet base).
2)
Connect the enclosed DOL 278AT connection cable (
B
).
3)
Fasten the five conductors in the terminal strip (
C
) Q1-Q5.
4)
Connect the twelve-pole cable in DOL 278AT (
D
) in the terminal strip T1-T12. (The cable can
be replaced by a longer one (max. 3 m.), run it through the cable glands).
5)
Set the climate computer jumpers (
E
) (see section 5.5.4.1).
Figure 3: Connecting the DOL 278AT emergency opening system and setting the basic module and I/O
module jumpers.
13.5.1 Setting of Jumpers
Function
Jumper Setting
Outdoor
temp.
compensation
J7 (
M
)
OFF
: Outdoor temp. compensation not
active
ON
: Outdoor temp. compensation active
(factory setting)
Run time
(for complete
opening of inlet)
J8 (
L
)
2 min.
(minutes) for: DA 74, DA 75-1, DA
75-3 winch motors (factory setting)
4 min.
(minutes) for: DA 75-6, DA 75-12
(slow) winch motors
Outdoor temp.
Motor Run Time
2 Min.
4 Min.
OFF
ON
J7
J8
Summary of Contents for DOL 278A
Page 2: ......
Page 14: ...14 Teknisk manual DOL 278T 5 5 3 Eldiagram DOL 278AT large DOL 278 Klimacomputer...
Page 30: ...30 Technical manual DOL 278T 13 5 3 Wiring Diagram DOL 278AT Large DOL 278 Klimacomputer...
Page 46: ...46 Technisches Handbuch DOL 278T 21 5 3 Schaltplan DOL 278AT Large DOL 278 Klimacomputer...
Page 54: ......