Positioning the Cabinet

Location

When positioning the cabinet, avoid direct sunlight and warm draughts etc. 
The cabinet must NOT be situated where it is affected by warm or hot air 
(above 40

°C)

 from adjacent equipment, as this will compromise the airflow 

and performance of the chiller.
The cabinet must be positioned on a level surface for the doors to shut and 
seal correctly, and to prevent the condensate tray from overflowing. 
Adequate allowance should be made for door opening.

Installation

Guidelines

The maximum recommended ambient temperature (at place of installation) 
for the chiller is 32°C. This chiller will generally use less power when 
installed in a cooler location.

When installing the cabinet:

Avoid direct sunlight and warm draughts etc.

Allow adequate space for the door/s to open fully.

Ensure the cabinet is positioned on a level surface so the door/s shut 

and seal correctly and to prevent the condensate tray from overflowing.

The self-closing door/s have internal torsion bars, pretensioned at the 

factory, and should not require any further adjustment. 

Do not overload the power supply. See the rating label inside the 

cabinet for power supply and current draw.

Power Supply

The chiller is supplied with a 1.8m flexible power cord fitted with a 3-pin plug, 

which exits out the rear of the refrigeration unit. The power cord should be 

retrieved before the cabinet is positioned, as wall and partitions may make 

access difficult.

WARNING:

Heat dispersion and ventilation of the refrigeration unit cannot 

be overstressed. The air surrounding the condenser must not 

exceed 40°C.

WARNING:

Do 

NOT

 overload the power supply. See the rating label inside 

the cabinet for power supply and current draw.

Summary of Contents for PG1300VF

Page 1: ...PG600 1300VF Vertical Freezer INTEGRAL User Manual MAN8826 Rev 4 0 Dec 2011 SKOPE PEGASUS PG600VF PG1300VF ...

Page 2: ...ww skope co nz Trademark Infringement The SKOPE trademark on this product is infringed if the owner for the time being does any of the following Applies the trade mark to the product after their state condition get up or packaging has been altered in any manner Alters removes including part removal or obliterates including part obliteration the trade mark on the product Applies any other trade mar...

Page 3: ...Loading Product 7 Door Lock 7 2 Operation Automatic Start Up 8 Refrigeration Unit 8 Electronic Controller 8 Cabinet Lighting 8 Electronic Controller 9 Controller Display 9 Controller Operation 10 Controller Alarms 10 Programming 11 Setpoint 13 Manual Defrost 13 Continuous Refrigeration 13 3 Servicing Lighting 14 Cabinet Interior Lights 14 Cleaning 15 Cabinet 15 Condenser Coil 15 Troubleshooting 16...

Page 4: ...to economical high performance Be careful not to touch moving parts and hot surfaces For your own safety and that of others ensure that all electrical work is done by authorised personnel If the power supply flexible cord becomes damaged it must be replaced by an authorised service agent or similarly qualified person in order to avoid a hazard Ensure all necessary safety precautions are observed d...

Page 5: ...ct sunlight and warm draughts etc Allow adequate space for the door s to open fully Ensure the cabinet is positioned on a level surface so the door s shut and seal correctly and to prevent the condensate tray from overflowing The self closing door s have internal torsion bars pretensioned at the factory and should not require any further adjustment Do not overload the power supply See the rating l...

Page 6: ...tons or other items on top of the refrigeration unit When positioning the cabinet a gap of at least 200mm must be left above the refrigeration unit The back of the cabinet can be positioned hard against a wall however a gap of 50mm is recommended to prevent moisture build up IMPORTANT To ensure efficient and reliable operation a minimum of 200mm clear ventilation space is required above the refrig...

Page 7: ...nt of the shelf as this could prevent the doors from shutting Leave an airspace of at least 50mm above product loaded on the top shelf Products must NOT be stored on the floor of the cabinet Do not exceed a maximum loading of 20kg per shelf Remove some product if the shelves are flexing or bending Door Lock Each door has a key lock located at the top of the door on the same side as the handle 1 Un...

Page 8: ...r will continue to circulate at all times The compressor will start after approximately one minute The compressor will switch off when the cabinet internal temperature reaches approximately 21 C and on again at approximately 18 C Electronic Controller When the cabinet is connected to the power supply Cabinet Lighting The interior lighting will go on when a cabinet door is opened To replace an LED ...

Page 9: ...s selected parameter in parameter mode Allows entry to configuration parameters section if pressed simultaneously with PRG key for 5 seconds 3 Adjustment locked out Alters parameters in parameter mode Activates and deactivates continuous refrigeration mode with def key 4 Adjustment locked out Activates manual defrost cycle Alters parameters in parameter mode Activates and deactivates continuous re...

Page 10: ...roller displays NOTE Alarm HI may activate during initial pull down cycle after being first powered up The alarm can be muted and will automatically reset when the cabinet passes the alarm setpoint To reset an alarm Alarm code Description Faulty ambient probe Faulty defrost probe High pressure fault Low minimum temperature alarm High maximum temperature alarm Defrost timed out Data acquisition fai...

Page 11: ...s it is recommended that the keypad is locked see over page for instructions on how to lock the keypad To unlock the keypad Parameter Setting Description H2 00 Keypad locked H2 01 Keypad unlocked 1 Press and hold both the PRG and SEL keys simultaneously for more than 5 seconds until 00 is displayed 2 Press the UP aux key until 22 is displayed 3 Press the SEL key to confirm selection The first para...

Page 12: ... key until 22 is displayed 3 Press the SEL key to confirm selection The first parameter C is displayed 4 Press the DOWN def key twice until H2 is displayed 5 Press the SEL key to display the value of the parameter 6 Press the UP aux key to increase or the DOWN def key to decrease until 00 is displayed 7 Press the SEL key to accept the value 8 Press the PRG key to lock in the new value and to exit ...

Page 13: ...and hold both the PRG and SEL keys simultaneously for more than 5 seconds until 00 is displayed Factory setting 21 C Maximum 16 C Minimum 26 C 1 Unlock the keypad 2 Press the SEL key for 1 second and the Setpoint value will be displayed On releasing the key the display will flash 3 To change the Setpoint value press the UP aux or DOWN def keys 4 Press the SEL key to lock in the value and return to...

Page 14: ... light tube Cabinet LED tube description SKOPE part No PG600VF Ecopoint 5W 360mm T8 LED tube ELL10435 PG1300VF Ecopoint 22W 1200mm T8 LED tube ELL10436 1 Disconnect the chiller from the mains power supply 2 Remove the diffuser by squeezing it until it is released from the housing and then push the diffuser out of the way single door cabinet pictured for clarity 3 Rotate the LED tube until the pins...

Page 15: ...hould be brushed clean once a month and blown clean by qualified service personnel every six months Over time dust may accumulate within the condenser that cannot be removed with a brush if this occurs contact SKOPE to arrange for a SKOPE Authorised Service Agent to clean the condenser with compressed air To access the condenser coil CAUTION Disconnect the cabinet from the mains power supply befor...

Page 16: ... Unit operating too hot Clean condenser Ensure the chiller is installed with good ventilation above the refrigeration unit Cabinet doors are opened excessively Keep door s open for minimum time 4 Product is too warm and spoiling Restricted cabinet airflow Ensure product is not blocking airflow slots and the product is no closer than 50mm from the cabinet top Temperature setpoint is too warm Adjust...

Page 17: ...church New Zealand Freephone 0800 947 5673 Fax 03 983 3896 E mail enquiry skope co nz Website www skope co nz AUSTRALIAN CONTACT A B N 73 374 418 306 PO Box 7543 Baulkham Hills B C NSW 2153 Australia Freephone 1800 121 535 Fax 1800 121 533 E mail enquiry skope com au Website www skope com au ...