Servicing
Lighting
Cabinet
Interior Lights
The cabinet interior is lit by an LED tube fitted behind the diffuser at the top
of the cabinet (PG600VF) or behing the centre pillar (PG1300VF). See the
table below for LED tube specifications.
LED tube specifications
To replace the interior LED light tube
Cabinet
LED tube description
SKOPE part No.
PG600VF
Ecopoint 5W 360mm T8 LED tube
ELL10435
PG1300VF
Ecopoint 22W 1200mm T8 LED tube
ELL10436
1. Disconnect the chiller from the mains power supply.
2. Remove the diffuser by
squeezing it until it is
released from the
housing, and then push
the diffuser out of the way
(single door cabinet
pictured for clarity).
3. Rotate the LED tube until
the pins on the ends of the
tube align with the slots,
then slide it out.
4. Fit a new LED tube and
clip the diffuser back into
place. Reconnect to the
power supply.