background image

7

SC112N-AC

Operation

User Manual

Electronic Controller

Introduction

The electronic controller controls and displays the chiller temperature, and 

signals temperature alarms. It uses temperature probes and a door switch 

to collect data and runs the chiller accordingly. The electronic controller 

automatically switches the chiller between ‘Day’ and ‘Night’ modes 

depending on chiller usage. The electronic controller is pre-programmed 

and requires no initial setup or additional programming. SKOPE does not 

recommend that the settings be changed unless it is absolutely necessary. 

To ensure efficient operation, the electronic controller forces a defrost cycle 

when required.

Faceplate

Because the electronic controller plays such an important role, it’s helpful to 

know the parts of the faceplate you may use.

Door Switch

The front door (electronic controller side) is fitted with a door switch which 

tells the electronic controller when the door is opened and closed. If the door 

is opened for an extended period an alarm will sound. Press the alarm mute 

button on the electronic controller to mute the alarm.

1

2

6

3

5

4

7

8

9

No.  Item Description

1

Alarm Mute (up):

 Mutes the audible alarm buzzer.

2

Day - Night:

 Switches the chiller between ‘Day’ and ‘Night’ modes.

3

Light (down):

 Switches the cabinet lights on and off.

4

Compressor: 

ON when the compressor and condenser fan starts. 

Flashes when activation of the compressor is temporarily delayed.

5

Fan:

 ON when the internal cabinet fans are activated. Flashes 

when activation of the fans is temporarily delayed.

6

Defrost:

 ON when the defrost is activated. Flashes when the 

defrost is temporarily delayed due to other procedures in progress.

7

AUX: 

n.a.

8

Clock:

 n.a.

9

Alarm:

 ON when an alarm is signalled.

Summary of Contents for HSC112NA

Page 1: ...User Manual MAN80260 Rev 1 1 Jan 2022 SC112N AC Four Glass Sided Chiller Type HSC112NA...

Page 2: ...www skope com Trademark Infringement The SKOPE trademark on this product is infringed if the owner for the time being does any of the following Applies the trade mark to the product after its state co...

Page 3: ...5 Installation Guidelines 5 Power Cord 5 Levelling 5 2 Operation Automatic Start up 6 Loading Product 6 Door Lock 6 Electronic Controller 7 Introduction 7 Faceplate 7 Door Switch 7 Controller Operati...

Page 4: ...work is done by authorised personnel If the power supply flexible cord becomes damaged it must be replaced by an authorised service agent or similarly qualified person in order to avoid a hazard Ensur...

Page 5: ...installing the chiller Remove all packaging material from the inside and outside the chiller Ensure the chiller is positioned on a level surface so the doors shut and seal correctly and to prevent th...

Page 6: ...ty door locks Use the supplied keys to lock and unlock the door as necessary Item Activity Condenser fan The condenser fan starts immediately and can be heard Evaporator fan The evaporator fan will st...

Page 7: ...he parts of the faceplate you may use Door Switch The front door electronic controller side is fitted with a door switch which tells the electronic controller when the door is opened and closed If the...

Page 8: ...r lights will switch off To switch the chiller between Day and Night modes manually press and hold the Day Night button on the electronic controller faceplate The chiller can also be bought into Day m...

Page 9: ...witched into Day mode by pressing the Day Night button on the electronic controller faceplate Alarm code Buzzer Alarm LED Description Reset Off On CO2 condenser high temperature pre alarm status Autom...

Page 10: ...ree wire shelves which may be positioned at different heights to suit various products Each shelf is held in place with four shelf clips which engage in the shelf support strips To adjust the cabinet...

Page 11: ...ge a service call Failed LED light Arrange a service call Sign and interior lights will not switch off Chiller is in Cold Climate Protection CCP mode It is not possible to turn the lights off when the...

Page 12: ...SKOPE Contacts SKOPE Industries Limited ABN 73 374 418 306 AU 1800 121 535 NZ 0800 947 5673 skope skope com www skope com...