Notch
Complaint
Possible Cause
Repair
1. Cabinet not
operating and no
controller display:
• Loss of power
supply.
• Check mains power supply and
check the cabinet isolating switch is
turned on (see “Isolating Electrics”
on page 12).
2. Cabinet interior
light not
operating:
• Failed
fluorescent tube.
• Replace fluorescent tube (see
• Controller alarm.
• Determine cause and eliminate
(“Controller Alarms” on page 10).
• Not switched on
• Switch on at controller (some
models only, see “Controller Display”
on page 9)
3. Power
consumption is
higher than
expected:
• Unit operating too
hot.
• Clean the condenser coil (see
“Cleaning” on page 13). Ensure the
chiller is installed with good
ventilation around the refrigeration
unit and within its maximum
operating temperature (see
“Positioning the Cabinet” on page 5).
• Cabinet door is
opened
excessively.
• Keep door open for minimum time.
4. Product is too
warm and
spoiling:
• Restricted
cabinet airflow.
• Ensure product is not blocking
airflow slots and there is air space
around all the product.
• Temperature
setpoint to too
warm.
• Adjust setpoint (“Temperature
5. Warm cabinet
temperatures
and/or
compressor
operating for long
periods (more
than 1 hour):
• Blocked
condenser.
• Clean the condenser coil (see
• Poor refrigeration
unit ventilation.
• Ensure the cabinet is installed with
good ventilation around the
refrigeration unit and within its
maximum operating temperature
(see “Positioning the Cabinet” on
page 5).