12
Servicing
User Manual
SKOPE B550/660-2 and BME550-2
3
Servicing
Isolating Electrics
The refrigeration unit can be totally isolated from the mains power,
irrespective of whether the refrigerator is plugged into the mains. To achieve
this, switch off the mains isolating switch and disconnect the refrigeration
unit mains flex
To isolate the cabinet
1. Disconnect cabinet from the power supply.
2. Remove cabinet kick panel, by loosening the screws along top back
flange of the kick panel. Raise the kick panel vertically to clear keyholes
off the screw heads, then tilt panel forward and lift up and off the bottom
fixing brackets. Access to top screws can be made easier by opening
the cabinet doors.
3. Remove the controller from the kick panel, by loosening the two top
fixing screws through the top slots in the kick panel.
4. Switch off isolating switch, and unplug refrigeration unit mains flex from
the mains isolating box.
Figure 8:
Removing the Controller
Figure 9: Mains Isolating Box
Mains Isolating Box
Isolating Switch
Refrigeration Unit
Mains Flex
Fixing Screws
Controller