69
SKOPE TME ActiveCore
Replacement Procedures
Service Manual
Unit Cover
Remove the unit cover to access parts within the unit assembly.
To remove the unit cover
Condenser
Fan
The condenser fan assembly is made up of a fan motor, fan blade and
mounting brackets which can be replaced if necessary.
If the fan stops for any reason, check all connections to ensure no plugs
have come loose. Refer to the label on the electrics box cover to identify the
condenser fan plug and socket in the electrics box.
It is important that the fan blade and/or fan motor is replaced with the same
part to ensure correct alignment and refrigeration performance. Fan blades
should be tightened to the fan motor manufacturer recommended torque
settings (shown in the table below).
Fan motor manufacturer recommended torque settings
To access the condenser fan assembly
1. Isolate the chiller from the power supply and remove the refrigeration unit
(see page 66).
2. Unscrew the four machine
screws from the sides of
the refrigeration unit and
lift the cover off the unit.
Fan motor manufacturer Torque setting
EBM
1.4 N m
Wellington Drive
2.1 N m
1. Isolate the chiller from the power supply and remove the refrigeration unit
2. Remove the unit cover (see page 69).
3. Open the electrics box and unplug the condenser fan motor plug (see
4. Cut the cable ties
holding the cables along
the base of the unit, and
free up the condenser
fan motor cable.