![Skope ActiveCore SKT series Service Manual Download Page 67](http://html1.mh-extra.com/html/skope/activecore-skt-series/activecore-skt-series_service-manual_1289182067.webp)
67
SKOPE TME ActiveCore
Replacement Procedures
Service Manual
Replacing the
Unit
The SKOPE ActiveCore refrigeration unit is interchangable between bottom
and top mount ActiveCore chillers.
When interchanging from a bottom mount chiller to a top mount chiller, an
evaporator lid, strap brackets and hold down brackets must be fitted to seal
the top of the evaporator tub, and to fix the unit to the top of the cabinet.
New spare part refrigeration units supplied by SKOPE are not supplied with
the evaporator tub lid, top strap brackets and hold down brackets. When
replacing a faulty top mount refrigeration unit, retain these parts for use on
the new spare part replacement unit.
The evaporator tub lid, top strap brackets and hold down brackets can be
ordered in addition to the refrigeration unit if required. See page 27 for spare
part numbers.
To replace a unit with a SKOPE supplied spare part refrigeration unit
Evaporator
tub lid
Top strap
brackets
Hold down
bracket
Hold down
bracket
Bottom plugs
1. Isolate the chiller from the power supply and remove the existing unit (see
2. On the new unit, push the bottom plugs out of the bottom of the evaporator
box.
3. Swap the evaporator tub lid, top strap brackets and hold down brackets
from the existing unit to the new unit.
4. Fit the new unit to the cabinet.