26
Miter-angle adjustment
1. Loosen the miter-lock knob approximately one-half turn.
2. Lift and hold the
miter-detent-release lever with your index finger. The miter-detent pin will
override the miter detents and you can hold the
miter-lock knob with other fingers to rotate
the miter table until the miter-angle pointer aligns with the desired angle on the miter scale
(Fig.20a).
Alternatively, lift the
miter-detent release lever while pushing the miter-detent override
forward until it is engaged into the slot. The miter-detent pin will also override the miter
detents and you can simply hold the
miter-lock knob to rotate
the miter table until the
miter-angle pointer aligns with the desired angle on the miter scale (Fig.20b).
3. Tighten the miter-lock knob.
4. You can set 0°,15°,22.5°,31.6°, and 45° right/left miter angles quickly. Move the miter
table close to your desired angle detent by following steps 1 to 3 above. Lift the
miter-
detent-release lever while pulling the miter-detent override backward until it is completely
disengaged from the slot.
Hold the miter-lock knob to rotate the miter table toward your
desired angle detent until the miter-lock pin is snapped into the detent automatically
(Fig.21 )
. Tighten the miter-lock knob after your adjustment.
1
2
Fig. 20a
Miter-detent pin
Miter-detent
Miter-detent release level
Miter- lock knob
1
2
3
Fig. 20b
Miter-detent
Miter-detent pin
Miter-detent release level
Miter- lock knob
Miter- detent
override
1
2
3
Fig. 21
Miter-detent
Miter-detent pin
Miter-detent release level
Miter- lock knob
Miter- detent
override