9
SKF TIH 220m
E
nglish
TIH 220m/MV, TIH 220m/LV with 200V-3 phases, and all other three phases
supply execution
Colour of TIH 220m/xx wire
Mains supply terminal
yellow / green
ground
blue
phase 1
brown
phase 2
Connect the TIH 220m to only two of the three phases.
TIH 220m/LV with single phase supply
Colour of TIH 220m/LV wire
Mains supply terminal
yellow / green
ground
blue
neutral
brown
phase 1
4. Preparation for use
•
Place the TIH 220m in the horizontal position on a stable surface.
•
Connect the mains plug to a suitable mains supply.
•
Plug the remote control into the connector on the carrying handle side of the heater.
•
Slide the sliding yoke in open position. See the illustrations at the beginning of
this manual.
•
For workpieces with an internal diameter large enough to it over the induction coil,
follow these steps:
- Open the foldable bearing support and position them as shown on the
illustrations at the beginning of this manual.
- Place the workpiece over the induction coil using appropriate lifting equipment.
- For best performance, adjust the position of the workpiece so that the induction
coil is in the centre.
- Close the sliding yoke so that it completely covers the top of both
vertical supports.
•
For workpieces that do not it over the induction coil, follow these steps:
- Choose the largest of the two yokes that it through the internal diameter
of the workpiece.
- Slide the workpiece onto the yoke that you have selected.
- Position the yoke on the TIH 220m with the bright underside resting evenly on
the two vertical supports.
•
If you will use TEMP MODE, plug the temperature probe into the connector on the
carrying handle side of the heater. Place the magnetic end of the probe on the inner
ring of the bearing or on the innermost surface of the workpiece.
•
Switch on the TIH 220m.
•
Observe the self-test of the remote control display and signal tone.
Summary of Contents for TIH 100m
Page 2: ......
Page 4: ......
Page 79: ...77 SKF TIH 220m TIH 220m 5 50cm TIH 220m TIH 220m TIH 220m TIH 220m TIH 220m TIH 220m TIH 220m...
Page 80: ...78 SKF TIH 220m 1 SKF TIH 220m 90 C 20 C 110 C 1 1 TIH 220m TIH 220m 1 2 TIH 220M TIH 220m...
Page 81: ...79 SKF TIH 220m 1 3 TIH 220m TIH 220m 2 100 50 C1 C2 2 1 TIH 220m U...
Page 90: ...88 SKF TIH 220m TIH 220m 5 50 1 6 TIH 220m TIH 220m...
Page 91: ...89 SKF TIH 220m 1 SKF TIH 220m 90 C 162 F 20 C 110 C 230 F 1 1 TIH 220m TIH 220m 1 2...
Page 92: ...90 SKF TIH 220m 1 3 TIH 220m TIH 220m 2 TEMP MODE TIME MODE 100 50 C1 C2 2 1 TIH 220m U...
Page 99: ...97 SKF TIH 220m 9 U U LGAF 3E...
Page 112: ...110 SKF TIH 220m...
Page 113: ...111 SKF TIH 220m Dansk...
Page 114: ...112 SKF TIH 220m...
Page 115: ......