26
Multilube-system monitoring
General
Daily inspections
x
control unit for trouble-free operation
Monthly inspections
x
check piping in locations which are exposed for external damages
Annual inspections (more often if needed)
x
cleaning of the filter of the filling connector
Doser inspections
Check the dosers after approximately one (1) month after system start-up and after that
check depending on the operating conditions, but at least after every 6 months. Check for
potential excessive or insufficient lubrication and adjust dosers, if necessary.
SMG dosers
Steps
1. Disconnect the lubrication pipes and hoses from the lubrication points.
2. Pressurize the lines.
3. Check that lubricant comes out of the lubrication pipes and hoses.
4. Connect the lubrication pipes and hoses to the lubrication points.
If lubricant does not come out of lubrication pipes or hoses, see Multilube / Troubleshooting.
B-dosers
Steps
1. Disconnect the lubrication pipes and hoses from the lubrication points.
2. Pressurize the line.
3. Check that lubricant comes out of the lubrication pipes and hoses.
4. Connect the lubrication pipes and hoses to the lubrication points.
If lubricant does not come out of lubrication pipes or hoses, see Multilube / Troubleshooting.