33
pressurization phase starts or if the line pressure does not rise high enough during pressurization time.
Alarm, high pressure
If the line pressure is not low enough at the beginning of the pressurization phase, code AHP is blinking on
the display and the red LED-signal L1 or L2 of the line that triggered the alarm is blinking.
In pressure transmitter operation an alarm is triggered, if the line pressure is above the set low limit when
pressurization starts. Pressurization will restart for the same line when the pressure level is below the low limit
value and the alarm has been reset by pressing the SET-button.
In pressure switch operation an alarm is triggered, if the pressure switch is closed when the pressurization
starts. Pressurization will restart for the same line when the pressure switch opens and the alarm has been
reset by pressing the SET-button.
Alarm, low pressure
If the pressure in the line does not rise high enough during pressurization time, code ALP is blinking in the dis-
play and the red LED-signal L1 or L2 of the line that triggered the alarm is blinking.
In pressure transmitter operation an alarm is triggered, if the line pressure does not reach the set high limit
within the set maximum pressurization time. Pressurization will restart for the same line when the alarm has
been reset by pressing the SET-button.
In pressure switch operation an alarm is triggered if the pressure switch of the line does not close within the
set maximum pressurization time. Pressurization will restart for the same line when the alarm has been reset
by pressing the SET-button.
10.3.3 Pulse alarm, ProFlex lubrication system
The channel triggers a pulse alarm ALP (Alarm Low amount of Pulses) and goes into alarm mode if the pulse
amount is not reached within the set maximum pressurization time.
10.3.4 Alarm from SKF Doser monitor -doser operation indicator
The SKF Doser monitors are in use when factory settings parameter LGI has been set in status YES.
An alarm will be triggered when the SKF Doser monitor does not recognize doser operation during a lubrica-
tion cycle. Code AIn is displayed. Lubrication continues normally despite the alarm. This feature is different
from other alarms. The alarm can be reset with the SET-button.