6
EN
6. Assembly
- 31 -
951-171-044-EN
Version 03
Initial filling Fig. 8
Filling position of the pump
Check the packing rings of the two
vent plugs for damage, replacing
them if necessary (see Chapter 14).
• Screw the two vent plugs (5) into the
vent boreholes (6) and tighten them
(
15 ± 0.1 Nm)
• Resume the filling process, switch on the
transfer pump (see Fig. 9)
Should it happen that the air inclu-
sions in the lower reservoir area are
not entirely displaced by the lubri-
cant, the HTL201 can be "burped"
lightly on its base (12).
• As soon as the lubricant threatens to
escape at one of the ventilation hoses
(3), that ventilation hose is to be pulled
carefully out of the lubricant reservoir
ventilation system (4)
10 mm
1
2
7
4
3
5 /6
8
10
11
3
12
9
5
6
Summary of Contents for Lincoln HTL 201
Page 57: ......