Installation Instructions
Pump P 215
810-55192-1
Page 24 / 45
Rev. 012
2018/11/30
6.
Technical data of motors
Pump model
215-M100-M490
215-M049
215-M100-M490
215-M049
Unit
Motor type
DIC 63B4
DIC 63L4
DIC 63B4
DIC 63L4
Multi-range
Single-range
Frequency
50
60
50
60
50
50
[Hz]
Rated power
0,18
0,21
0,25
0,28
0,18
0,25
[kW]
Rated speed
1370
1640
1350
1680
1370
1336
[min
-1
]
Rated current
at 220 - 240 V
1,38
2,40
[A]
at 380 - 420 V
0,80
1,40
[A]
at 250 - 275 V
1,38
2,80
[A]
at 440 - 480 V
0,80
1,60
[A]
at 290 V
1,11
1,66
[A]
at 500 V
0,64
0,96
[A]
Run-in current
3
3,6
2,5
2,6
Factor
Performance
factor
0,67
0,69
0,7
0,7
[cos φ]
Degree of
effectivity
61
65
47
43
[η %]
Type of
protection
IP 55
IP 55
IP 55
IP 55
Insulation class
F
F
F
F
Construction
size
63
63
63
63
Construction
type
B14
B14
B14
B14
Weight
4,4
5,0
4,4
5,0
[kg]
Flange
Ø 90
Ø 90
Ø 90
Ø 90
[mm]
Shaft end
Ø 11 x 23
Ø 11 x 23
Ø 11 x 23
Ø 11 x 23
[mm]
The above mentioned motors can be operated in the following power networks.
Voltage
Frequency Tolerance
230/380 V
50 Hz
±
5 %
230/400 V
50 Hz
± 10 %
240/415 V
50 Hz
±
5 %
254/440 V
60 Hz
±
5 %
265/460 V
60 Hz
±
5 %
480
V
60 Hz
±
5 %
290/500 V
50 Hz
± 10 %
Motors for other power networks (special versions) on request
Condensation drain holes
In case of operation at high humidity and significant temperature variations, the motors should
be provided with condensation drain holes and space heaters.
Summary of Contents for Lincoln 215-M049
Page 1: ...Installation Instructions Pump P 215 810 55192 1 Page 1 45 Rev 012 2018 11 30 P 215...
Page 23: ...Installation Instructions Pump P 215 810 55192 1 Page 23 45 Rev 012 2018 11 30...
Page 43: ...Installation Instructions Pump P 215 810 55192 1 Page 43 45 Rev 012 2018 11 30 M100 M049 100XY...