Installation Instructions
Pump P 215
810-55192-1
Page 22 / 45
Rev. 012
2018/11/30
5.
Technical data of the ultrasonic sensor
High-level signal / low-level signal / minimum switching distance
Reservoir
Switch point: high-level signal A
Switch point: low-level signal B
4 XYBU
approx. 65 mm
approx. 180 mm
8 XYBU
approx. 65 mm
approx. 245 mm
10 XYBU
approx. 65 mm
approx. 210 mm
30 XYBU
approx. 65 mm
approx. 420 mm
100 XYBU
approx. 220 mm
approx. 670 mm
The minimum distance between the lubricant and the ultrasonic sensor totals 60 mm. If this
distance is underrun, incorrect measurement results may occur due to undefined ultrasonic
sensor switching conditions.