Installation
The motor-driven pump unit should be ins-
talled in a location that is protected from
moisture and vibration, but should be readily
accessible.
The main lines to the lubrication points
should be laid with an upward inclination if
possible (air bleeding). Lubricant distributors
at the end of the lubrication system should
be installed with the lubrication point lines
pointing upward.
Hand tighten the tube fittings, then
tighten them by 1 1/2 turn.
!
The supply voltage on site must
agree with the information on the
nameplate. Check the fusing of the cir-
cuit. Use only the original fuse with the
required ampere value. If other fuses are
used, damage to property of personal
injury may be the consequence.
The motor-driven pump unit can be directly
mounted on a flat and horizontal surface.
Four fixation holes Ø6,5 are on the base of
the unit, set on a circle Ø85 at 90° from each
other (
†
fig. 2
)
The motor-driven pump unit GSJB can
also be mounted on the vertical wall with the
support plate GSJ1096 (
†
fig. 3
).
Ø6,5
Ø85
Fig. 2
Drilling template for pump unit.
4
16
Ø9
232
4×M6
Ø85
200
175
12
2,
5
20
0
50
16
Fig. 3
Bracket support GSJ1096
16