How to Operate the Strobe Light
Power Up Features
Strobe Light
4 - 9
User Manual
output pulse (and image) - refer to the
Phase Analysis
section later in this manual for adjusting the Phase
Angle control.
After the unit is in either the wide or narrow lock
mode and a steady RPM is established, tracking may
be turned on.
To turn on Filter Tracking:
•
Press the
ALT FUNCTION
button and then the
PHASE DELAY
button. The strobe displays
TRACK
for a moment.
The Wide or Narrow bandpass filter automatically
attempts to track input RPM. This is useful if you
want to see how the vibration changes over a wide
RPM range. It will track as long as the RPM does not
change too quickly. As RPMs change, the phase of the
image is likely to change as the filter tracks.
To turn off Filter Tracking:
•
Press the
ALT FUNCTION
button and then the
PHASE DELAY
button. The strobe displays
NO
TR
for a moment.
Power Up Features
When the strobe is powered up it will remember the
last settings.
To display segments, software revision, and
diagnosis:
•
Press and hold the
x2
/
MENU
button, then turn
on the strobe by depressing the trigger switch.
This turns on all the display segments for two
seconds or until you release the button. It will