How to Operate the Strobe Light
Lock Modes – Accelerometer Input Required
Strobe Light
4 - 7
User Manual
appear to rotate at a given (virtual) RPM or RPS. The
knob sets this virtual RPM or RPS.
To enter one of the External Delay modes:
•
Ensure there is an external input connected (so
the unit is in External Mode).
•
Press the
PHASE DELAY
button to cycle to the
desired mode.
•
Use the knob to adjust delay / angle (phase, time
or virtual RPM).
To exit the External Delay mode:
•
Press the
PHASE DELAY
button to cycle back to
External only. The
PHASE,
TIME
, or
AUTO
icon
disappears.
Lock Modes – Accelerometer Input Required
In the LOCK modes, the vibration transducer
(accelerometer) controls the flash rate. Prior to
setting the LOCK mode, the strobe must be operated
in Internal Mode. The accelerometer must be
properly connected and powered, usually by the
Microlog, and must be mounted in place.
Once set up, tune the strobe to set the center
frequency of the filters to work with the
accelerometer.
To tune the strobe:
•
Using Internal mode, adjust the flash rate of the
strobe to stop motion of the target of interest.
•
Press the
INPUT
/
MEMORY
button until the
LOCK
icon displays. The strobe will now use the