CARE / MAINTENANCE
12-3
Check the batteries frequently for signs of corrosion. If corrosion is evident, clean terminals with a baking soda
and water solution and a wire brush. Before cleaning, remove the vent caps and seal the vent wells with corks
to prevent the solution from getting inside the battery.
NOTE: S
ome batteries are sealed and cannot be filled.
Check the fluid levels in the cells. Usually, a level approximately 1/4 to 1/2 inch (6 to 13 mm) above the plates is
sufficient. If needed, fill with distilled water. DO NOT overfill!
• Batteries contain sulfuric acid which can cause severe burns. Wear
protective clothing to avoid acid contact with your skin and eyes. Failure to
do so could result in severe injury.
• The battery compartment doors MUST be secured in the open position for
ventilation when charging any batteries.
• Be sure to inspect your boat for and eliminate fuel fumes and their cause
prior to connecting a battery charger to your batteries.
WARNING
Section 12_2009.qxd:Section 12_horiz.qxd 1/20/09 9:23 AM Page 12-3