SKAARHOJ Eth-SDI Link

SDI Shield 

The Eth-SDI Link uses the Blackmagic Design 3G-SDI Shield. The Blackmagic 3G-SDI Arduino Shield 
supports the following formats using SDI Level B:

 

720p50, 720p59.94, 720p60, 1080i50, 1080i59.94, 

1080i60, 1080p23.98, 1080p24, 1080p25, 1080p29.97, 1080p30, 1080p50 (output only), 1080p59.94 
(output only) and 1080p60 (output only), but the camera doesn´t have to be running the same video 
format as the program input, so you can use cameras in Ultra HD while the camera protocol is sent over 
HD signal to the camera. 

 

Troubleshooting 

Error on Check: Your controller is not yet registered 

After pressing Update Firmware a message from the Firmware Updater stating that the connected 
controller is not fully registered yet may pop up. The Eth-SDI Link uses Stand Alone firmware and is not 
updated through the “Update Firmware” button on the firmware updater. 

To upload the latest Eth-SDI Link firmware please see the “Updating Firmware” section of this manual. 

If trying to change the IP address for the Eth-SDI Link please see the “IP Config” section of this manual. 

9

Summary of Contents for ETH-SDI

Page 1: ...ink The ETH SDI Link is used to translate UDP commands from a SKAARHOJ control panel to BMD Camera Control commands via SDI An alternate fi rmware is available for bridging a long connection from an Atem to BMD cameras for sending CCU data 1 ...

Page 2: ...d Firmware from File 7 Con fi rm Firmware Type and Version 7 Eth2SDI Firmware Change Log 8 Atem2SDI Firmware Change Log 8 SDI Shield 9 Troubleshooting 9 Error on Check Your controller is not yet registered 9 Controller does not show up under Port in Firmware Application 10 Controller Not Con fi rming Connection 11 Network Recommendations 11 Facts 11 Power over Ethernet PoE Speci fi cations 12 Trou...

Page 3: ...ween the ATEM and the camera and a VPN can be used to channel the network through In such a scenario the ETH SDI Link would establish a network connection to the ATEM and use it to extract the data otherwise embedded on SDI out of the switcher and embed it locally Requires low latency network When using the Eth SDI Link eith the Eth2SDI fi rmware in a Blue Pill environment it will automatically sw...

Page 4: ...SKAARHOJ Eth SDI Link Set Up Principal Networking Setups 4 ...

Page 5: ... using the base IP address 192 168 10 99 This is the the default and con fi g IP address of the ETH SDI Link even if the IP address was changed for operation mode Press Submit to save the settings Method 2 Starting with fi rmware version 1 6 the IP address can be set via the serial monitor with the serial command ip X X X X Example ip 192 168 10 90 Con fi rm Connection The serial monitor can be us...

Page 6: ...nter the web interface by using the base IP address 192 168 10 99 This is the the default and con fi g IP address of the Atem SDI Link even if the IP address was changed for operation mode Press Submit to save the settings Power cycle the device for the changes to take effect Con fi rm Connection The serial monitor can be used to con fi rm if connection have been established between the Atem SDI L...

Page 7: ...e from File is in the Options tab in the Firmware Application The function is used to for the Eth SDI Link Please note that though the SKAARHOJ Firmware Updater is needed to do fi rmware updates DO NOT use Update Firmware in the Firmware Application as this will render the fi rmware on the device useless If Update Firmware have been pressed please re upload the proper fi rmware hex fi le found in ...

Page 8: ...o negotiation disabled for better support for Linksys Switches Included version and product name printout in boot sequence v1 0 Initial release Atem2SDI Firmware Change Log v1 10 Update to latest ATEM library v1 9 Prevent fi rmware updater from uploading wrong fi le v1 8 Added support for ATEM 8 1 v1 7 Correct handling of relative focus values from ATEM Switcher v1 6 Focus fi x v1 5 Added statical...

Page 9: ...can use cameras in Ultra HD while the camera protocol is sent over HD signal to the camera Troubleshooting Error on Check Your controller is not yet registered After pressing Update Firmware a message from the Firmware Updater stating that the connected controller is not fully registered yet may pop up The Eth SDI Link uses Stand Alone fi rmware and is not updated through the Update Firmware butto...

Page 10: ...ur computer Boot the controller in con fi g mode Disconnect the controllers power then hold the con fi g button under the power plug down with a pen tip power on the controller and hold the button until it lights blue then release If none of the above brings up the USB port you may try this procedure but only after clearing it with the SKAARHOJ support team Locate the small hole just below the con...

Page 11: ... the IP Settings Make sure the IP for the Device Core in the connected SKAARHOJ controller is set to the same IP address as the Eth SDI Link Network Recommendations Facts SKAARHOJ controllers have a 100 mbps network interface Network switch must have Auto MDI MDIX Network switch must support 100 mbps PoE IEEE 802 3af SKAARHOJ controllers only support Half Duplex mode without Auto Negotiate When co...

Page 12: ...trical and electronic equipment WEEE should not be mixed with general household waste For proper treatment recovery and recycling please take this product s to designated collection points where it will be accepted free of charge Alternatively in some countries you may be able to return your products to your local retailer upon purchase of an equivalent new product Disposing of this product correc...

Reviews: