Mounting the control panel

NOTE

If the distance to the control panel exceeds the length of 

the pump power cord, splicing in a liquid-tight junction 

box will be required.  For outdoor or wet installation, we 

recommend an SJE-Rhombus, UL Type 4X junction box.

1

Drill and install top fastener using appropriate anchor if 

necessary.

2

Drill and install a bottom fastener using appropriate 

anchor if necessary.

English 2

Wiring the control panel

 

Features

The SJE Rhombus TimeZone

 Digital Timer control panel is designed to control one single phase motor

/

pump based on a digital timer.

The large LCD display and the rotary dial make the timer setup quick and simple.

The built-in circuit breaker provides protection and disconnect capabilities.

Additional features such as the “Service Alarm” will notify when it is time to replace a filter of service the system.  The MAN. ON and 

MAN. OFF toggle switch enables the user to start or stop the pump manually before the clock schedule, but automatically resumes 

normal operation at the end of the cycle.

1

Determine conduit entrance locations on control panel as 

shown.  

Disconnect all power to the control panel before wiring. 

Ensure that the incoming supply power voltage is the same 

as the rating of the pump motor being installed. Ensure that 

the rated Amps of the motor does not exceed the rating of 

the control panel.

2

Connect the following wires to the proper terminal positions:

• 

Incoming power to the circuit breaker

• 

Motor/Pump power to Motor

See schematic label on inside cover of the control panel for details.

CAUTION!

Technical support, 

service questions:

1-800-Rhombus

(1-800-746-6287)

Monday - Friday

7:00 AM to 6:00 PM Central Time

?

3

Verify correct operation of control panel after installation is 

complete.

English 3

Incoming 

power to 

main breaker 

panel

To 

motor

Circuit Breaker:

The pump circuit has a thermal-magnetic 

circuit breaker that provides pump disconnect 

and branch circuit protection.

LCD Display:

LCD display to show four timing ranges 

(turn on), current time, work mode and 

running status for motor.

24-hour LCD time graph accuracy (15 

minutes per each bar). 96 bars total.

Type 4X conduit must be used to maintain 

a Type 4X rating of the control panel.

Off-Auto-On Switch

The 3-way switch controls the pump 

functions.

ON 

(Momentary). The pump 

starts and stays ON until the next 

OFF timer sequence.

Encoder Switch:

Rotate/Enter select 

the menu or setting 

desired.

ESC button:

Exit without saving or jump to 

previous display.

AUTO

 (Maintained) the pump 

will operate according to the 

timer sequence

OFF 

(Momentary).  The pump 

stops and stays OFF until the 

next ON timer sequence.

Summary of Contents for TimeZone

Page 1: ...z Power Relay 2 pole 25A rated Operation Temperature 10 to 50 Part Number Circuit Breaker 1067561S 2 pole 16A for pumps rated for 0 12A 1067560S 2 pole 25A for pumps rated for 9 20A Clock Real Time clock with Super Capacitor power backup 5 days Accuracy Turn ON OFF time set accuracy 1 min Enclosure Thermoplastic TYPE 4X IP65 20 3 x 15 2 x 10 2 cm English 4 Operatation Guide A When turning the knob...

Page 2: ... is the same as the rating of the pump motor being installed Ensure that the rated Amps of the motor does not exceed the rating of the control panel 2Connect the following wires to the proper terminal positions Incoming power to the circuit breaker Motor Pump power to Motor See schematic label on inside cover of the control panel for details CAUTION Technical support service questions 1 800 Rhombu...

Page 3: ...n Precisión de ajuste de tiempo de encendido apagado 1 min Gabinete Termoplástico TIPO NEMA 4X IP65 20 3 x 15 2 x 10 2 cm Español 4 Guía de Operación A Cuando gire la perilla lentamente en sentido horario incremente en 1 minuto B Cuando gire la perilla en sentido horario más rápido que A incremente en 10 minutos C Cuando gire la perilla en el sentido de las agujas del reloj más rápido que B increm...

Page 4: ...e entrada sea la misma que la del motor de la bomba que se está instalando Asegúrese de que los amperios nominales del motor no excedan la capacidad nominal del panel de control 2Conecte los siguientes cables a las posiciones de terminales adecuadas Energía entrante al disyuntor Poder de Motor Bomba al motor Consulte los dibujos eléctricos en la cubierta interior del panel de control para obtener ...

Reviews: