Sixnet Slim Line Switch Installation Guide
Page 5 of 33
Lightning Danger: Do not work on equipment during periods of lightning activity.
Do not connect a telephone line into one of the Ethernet RJ45 connectors.
EMC (emissions and immunity)
–
CE per the EMC directive, EN 55022 or IEC 61326-1 or EN 61000-6-2/4
FCC part 15 and ICES 003; Class B.
See FCC statement on previous page.
Marine, maritime and offshore –
These devices, when installed in an appropriately IP rated enclosure, comply with the ABS
standards which is similar to DNV No. 2.4 and equivalent Lloyds.
See warning below.
For marine and maritime compliance, do not install this product within 5 meters of a
standard or a steering magnetic compass.
WEEE compliance –
These devices comply with the WEEE directive. Do not throw away these devices in the
standard trash. Contact Sixnet regarding proper disposal.
RoHS
RoHS compliance –
These devices comply with the RoHS directive and are consider lead and other hazardous
substance free.
Hazardous Locations
–
CE per ATEX directive and EN50021/EN60079-15 (Zone 2);
EEx nA II T4 X (-40°c
T
a
+85°C)
UL per UL1604 (Class I, Div. 2), Groups A,B,C,D (UL File # E192531)
CSA per C22.2/213 (Class 1, Div. 2), Groups A,B,C,D (cUL File # E192531)
See warnings below.
WARNING
(EXPLOSION HAZARD)
SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR
CLASS 1, DIVISION 2 (ZONE 2).
WARNING
(EXPLOSION HAZARD)
WHEN IN HAZARDOUS LOCATIONS, DISCONNECT POWER BEFORE
REPLACING OR WIRING UNITS.
WARNING
(EXPLOSION HAZARD)
DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN
SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS.
WARNING
(EXPLOSION HAZARD)
IN HAZARDOUS OR POTENTIALLY HAZARDOUS LOCATIONS, DO
NOT SEPARATE ANY PART OF THE UNIT WHEN ENERGIZED. USE
THE UNIT FOR INTERNAL CONNECTIONS ONLY.