![sitrex SM 3600 Assembly, Use And Maintenance Download Page 39](http://html1.mh-extra.com/html/sitrex/sm-3600/sm-3600_assembly-use-and-maintenance_1285856039.webp)
38
7.4
MAINTENANCE AND TESTING
To effect the lubrication of the blade hubs 1 and the testing of the belt tension 5, it is necessary to remove
the protective guard "A" (see page 32).
Once these operations have been completed, re-attach the protective guard "A" properly.
To change (or top up) the oil, remove the caps B & C from the gearbox 3.
Pour the oil into the hole of cap B until it comes out of the hole of cap C, and then put back both caps.
The quantity of oil needed for a complete change is 0.5 litres.
The type of oil used must be in accordance with regulation ISO 320 VG.
The maintenance table specifies how often the oil should be changed.
0.1