background image

C6547 Rev. A

eBEAM

ASSEMBLY INSTRUCTIONS

eBEAM is a straightforward, streamlined solution for adding power to your workstations. 
With adaptable legs, multiple beam lengths and cable management options that make it 
practically mess-free, eBEAM is simply powerful (and powerfully simple).

Summary of Contents for eBEAM

Page 1: ...S eBEAM is a straightforward streamlined solution for adding power to your workstations With adaptable legs multiple beam lengths and cable management options that make it practically mess free eBEAM is simply powerful and powerfully simple ...

Page 2: ... Harness 1 Middle Clip 1 Duplex Receptacles 4 Power Infeed 1 Hose Clamp 1 10 24 Screw 1 5 16 18 Screws 5 16 18 10 24 Screws Ganging Bracket Jumper Component quantities shown are for a standard 2 seat back to back configuration Quantities will vary with user specifications For more information see the table on page 22 For accessory components see page 12 Data adapters are not included See page 23 f...

Page 3: ...S STEPS 1 Note We recommend reading these instructions in their entirety and laying all components out in advance 1 Remove cover from beam and set aside 2 If duplex receptacles were purchased set them into the power distribution harness with the arrows pointing up then slide outwards to snap them into place Beam Cover Duplex Receptacle Power Distribution Harness SNAP 2 3 ...

Page 4: ...ith the pre installed mounting bracket ensuring that the arrows on both the distribution harness and the duplexes point up Hook the bottom harness clips first then rotate slightly and apply pressure to snap the top harness clips into the mounting bracket The mounting bracket is pre installed on the inside center of the beam Place the middle clip over the distribution harness and attach it to the m...

Page 5: ...s leaving at least a 3 gap in one of the bottom slots for the power infeed and spacing from the open ends of the beam for the end caps 5 If attaching multiple beams From within the ganging bracket inside of the beam shown inverted above fasten the ganging bracket using the hex L key to install two 10 24 screws up into the inside bottom of the beam and four 10 24 screws down into the inside top of ...

Page 6: ...beam 8 Place the wire tray s in position and then secure the trays to the mounting plates by using the 3 16 hex L key to fasten two 5 16 18 per mounting plate 9 If attaching multiple beams From within the ganging bracket inside of the beam shown inverted above fasten the ganging bracket using the hex L key to install two 10 24 screws up into the inside bottom of the beam and four 10 24 screws down...

Page 7: ...he wire tray Slide in one mounting plate for each leg and set of wire tray tabs The mounting plates for the legs can be placed inside or outside the wire trays outer mounting plates Note Leave at least a 3 gap in the bottom slot for the infeed and spacing from the open ends of the beam for the end caps Some mounting plates or screws may be left over after installation 11 Place the legs in position...

Page 8: ...er infeed into the nearest distribution harness ensuring that the arrows on both the distribution harness and the power infeed point upwards 13 If attaching multiple beams together Plug one end of the jumper into each beam s distribution harness ensuring that the arrows on both the distribution harnesses and the jumper point up Note The jumper and infeed can be plugged in next to each other if the...

Page 9: ...Position the hose clamp above one of the bottom slots and fasten it to the thread feature on the upper inside of beam with a 10 24 screw using the hex L key 16 Hold the power infeed within the hose clamp opening and slide the 20 1 screw through the hose clamp holes Then tighten the 20 hex nut onto the screw using a 2 Phillips screwdriver Connection to building wiring must be done by a qualified el...

Page 10: ... adapters from tree and snap into data faceplates then snap in respective data modules etc not supplied 18 Snap blank faceplates and or data faceplates into window cutouts on the beam and beam cover 19 Route data cables through bottom slot of the beam and connect into data modules Then align and snap the beam cover back onto the beam 19 17 18 Data Modules Are Not Included DATA FACEPLATE BLANK FACE...

Page 11: ...sh the beam For optional screen assembly complete steps 21 26 and continue from there 20 Align end caps with square shapes and bottom opening at each end of the beam and pound flush into place with a non marring mallet hammer then peel off protective film If no additional accessories were purchased the beam is now complete For other optional accessories reference Power infeed cover installation pa...

Page 12: ...SSORY COMPONENTS 8 Screws 5 16 18 Screws 8 5 16 18 10 24 3 16 10 24 3 16 Screws Screen Screen Per Mount U Bracket 2 Halves Mounting Bar 1 M4 12 mm Screw 2 M6 20 mm Screw 1 M6 35 mm Screw 1 Gasket 2 M6 35 mm M6 20 mm M4 12 mm PER MOUNT U Bracket Side A U Bracket Side B M6 20 mm M6 35 mm Mounting Bar M4 12 mm Screen Wire Manager Clips Component quantities are per accessory Quantities will vary with ...

Page 13: ...25 Parts and instructions are per mount There are two mounts included with 48 screens or three mounts included with 60 72 screens Highest Point Highest Point 21 Separate U bracket halves 22 One side of the U bracket side A has screw holes Loosely attach the A side of the U bracket to the mounting bar using two M4 12 mm screws and a 2 Phillips screwdriver Note Mounting bar direction varies with scr...

Page 14: ...the U bracket mounting bar assemblies from the end of the beam into position Tighten the M4 12 mm screws with a 2 Phillips screwdriver 24 Slide the B side of the U bracket onto the A side Attach the two sides together using the M6 screw that is appropriate for the screen material and a 5 mm hex L key Do not close Make sure to leave a gap for the screen 25 First insert the gaskets pressing them aga...

Page 15: ...TRUCTIONS STEPS 26 26 Align end caps with square shapes and bottom opening at each end of the beam and pound flush into place with a non marring mallet hammer then peel off protective film If no additional accessories were purchased the beam is now complete For other optional accessories reference Power infeed cover installation page 16 Vertical wire manager pages 17 20 15 ...

Page 16: ...CES OUTWARD Hook and Loop Space for Infeed and Data Cables 27 For optional power infeed cover assembly To install the infeed cover remove backing from all pieces of the hook and loop Slide over position around legs and cables Provide pressure onto both sides of the exterior of the infeed cover for at least 30 seconds to set the hook and loop adhesive Note The open end of the infeed cover will face...

Page 17: ...4 For more information visit www sitonit net EBEAM ACCESSORY ASSEMBLY INSTRUCTIONS STEPS For optional vertical wire manager assembly choose one of the installation styles above Then complete steps 28 30 FINISHED LATERAL INSTALLATION FINISHED PERPENDICULAR INSTALLATION FINISHED VERTICAL INSTALLATION 17 ...

Page 18: ...ing two 10 24 3 16 screws and a 2 Phillips screwdriver Align to one of the three wire tray cut outs Lateral or perpendicular installation Attach the first wire manager clip to the top side of the wire tray using two 10 24 3 16 screws and a 2 Phillips screwdriver Align to a set of predrilled holes found left or right of center 28 Wire Tray Cutout LATERAL INSTALLATION VERTICAL INSTALLATION Wire Tray...

Page 19: ...SSEMBLY INSTRUCTIONS STEPS LATERAL INSTALLATION VERTICAL INSTALLATION Back Table Edge 29 29 Attach the second wire manager clip to the underside of the adjacent table top and use a Phillips 2 driver to fasten with two 8 wood screws Snap the ends of the carrier into the installed wire management clips PERPENDICULAR INSTALLATION Back Table Edge Back Table Edge 19 ...

Page 20: ...t at 888 274 8664 For more information visit www sitonit net EBEAM ACCESSORY ASSEMBLY INSTRUCTIONS STEPS 30 Note To change the direction of the the wire management curvature links can be detached and rotated 180º LATERAL INSTALLATION PERPENDICULAR INSTALLATION VERTICAL INSTALLATION 20 ...

Page 21: ...mbling this product Do not change or replace components and accessories provided by SitOnIt Seating PROFESSIONAL ASSISTANCE REQUIRED Connection to the building wiring must be completed by a qualified electrician NON LOAD BEARING Beam is not load bearing Do not place heavy objects on beam KEEP BEAM FRAME DRY Keep all electrical components away from water and humidity Not approved for outdoor use To...

Page 22: ... 18 24 30 6 12 18 24 30 Data Adapter Tree 1 2 3 4 5 1 2 3 4 5 Data Faceplate 2 4 6 8 10 2 4 6 8 10 Ganging Ganging Bracket 0 1 2 3 4 0 1 2 3 4 Jumper 0 1 2 3 4 0 1 2 3 4 10 24 Screw 0 6 12 18 24 0 6 12 18 24 Accessories 1 Seat 2 Seat 3 Seat 4 Seat 5 Seat 2 Seat 4 Seat 6 Seat 8 Seat 10 Seat Horizontal Wire Tray Wire Tray 1 2 3 4 5 2 4 6 8 10 Mounting Plate 3 6 9 12 15 6 12 18 24 30 5 16 18 Screw 4 ...

Page 23: ...GUAGE NEUTRAL 1 WHITE BLACK 10 GUAGE NEUTRAL 2 WHITE RED 10 GUAGE GROUND 2 GREEN YELLOW 12 GUAGE GROUND 1 GREEN OR BARE 12 GUAGE DISTRIBUTION END VIEW PLUG END VIEW WHITE BLACK N1 WHITE RED N2 RED L2 BLUE L3 GREEN OR BARE G1 PINK L4 GREEN YELLOW G2 BLACK L1 Specifications System rating 20A 120V 15 amp duplex receptacle Shared neutral wiring systems All shared neutrals use 10 guage wire rated at 35...