Installation:
·
Then press the bracket on the installation position, mark
installation hole of bracket with pencil.
·
Bore two installation hole on the sign with electric drill.
Make diameter of holes is 5mm, Strike the two plastic
plugs into holes with hammer.
·
Attach the bracket to the plastic plugs and fix tightly the
screws (3*25mm) into the plastic plugs. (refer to
Diagram 6).
Diagram 6
·
Fit the alarm on the bracket and turn the alarm body
clockwise, until matching well on the bracket.
·
Test smoke alarm using test button. The alarm will sound 3
short beeps – 1.5seconds pause, then repeat it until release
the button.
·
if no sound, it indicates a defective alarm, you can refer to
“Trouble shooting” for solution or return to your retailer
during warranty.
·
If you have any questions on installation, you can contact
your retailer.
·
During testing, may the other smoke detector will alarm.
Once release the button, others will stop alarming in 1
minute. In such a way, you can check the wireless
function.
WARNING:
·
To prevent injury, this unit must be securely attached to the
ceiling in accordance with the installation instructions.
·
Alarm must be actived by mounting the bracket before
operation
.
·
When the bracket is removed, the alarm power is turned off.
•
SERVICE AND WARRANTY
•
Company warrants to the original consumer. Purchase each
new smoke alarm to be free from defects in material and
workmanship under normal use and service for a period of
3 years from the date of purchase. This warranty does not
cover damage resulting from accident, misuse or abuse or
lack of reasonable care of the product. In no case shall
company be liable for any incidental or consequential
damages for breach of this or any other warranty express or
implied
,
whatsoever. The bad product can be mailed to the
following address with a detail explanation of problem.
•
If after reviewing this manual you feel that your smoke
alarm is defective in any way, do not tamper with the unit.
Return it for servicing to:
SITERWELL ELECTRONICS CO., LIMITED
ADDRESS: No.666 Qingfeng Road, Jiangbei District,
Ningbo, Zhejiang Province, China.
Tel: 0086-574-87729581
Fax: 0086-574-87729581
E-Mail: sales @ china-siter.com
Http://www.china-siter.com
holes of ceiling