Installation: 

·

Then  press  the  bracket  on  the  installation  position,  mark 

installation hole of bracket with pencil. 

·

Bore  two  installation  hole  on  the  sign  with  electric  drill. 

Make  diameter  of  holes  is  5mm,  Strike  the  two  plastic 
plugs into holes with hammer. 

·

Attach the bracket to the plastic plugs and fix tightly  the 

screws  (3*25mm)  into  the  plastic  plugs.  (refer  to 
Diagram 6).   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Diagram 6 

 

·

Fit  the  alarm  on  the  bracket  and  turn  the  alarm  body 

clockwise, until matching well on the bracket. 

·

Test smoke alarm using test button. The alarm will sound 3 
short beeps – 1.5seconds pause, then repeat it until release 
the button. 

·

if no sound, it indicates a defective alarm, you can refer to 

“Trouble shooting” for solution or return to your retailer 
during warranty.     

·

If you have any questions on installation, you can contact 
your retailer. 

·

During  testing, may  the  other  smoke  detector  will alarm. 
Once  release  the  button,  others  will  stop  alarming  in  1 
minute.  In  such  a  way,  you  can  check  the  wireless 
function. 

WARNING:

 

·

To prevent injury, this unit must be securely attached to the 

ceiling in accordance with the installation instructions.

 

·

Alarm  must  be  actived  by  mounting  the  bracket  before 

operation

.

 

·

When the bracket is removed, the alarm power is turned off.

 

 

SERVICE AND WARRANTY 

 

Company warrants to the original consumer. Purchase each 
new  smoke  alarm  to be  free  from  defects  in  material  and 
workmanship under normal use and service for a period of 
3 years from the date of purchase. This warranty does not 
cover damage resulting from accident, misuse or abuse or 
lack  of  reasonable  care  of  the  product.  In  no  case  shall 
company  be  liable  for  any  incidental  or  consequential 
damages for breach of this or any other warranty express or 
implied

whatsoever. The bad product can be mailed to the 

following address with a detail explanation of problem. 

 

If  after  reviewing  this  manual  you  feel  that  your  smoke 
alarm is defective in any way, do not tamper with the unit. 
Return it for servicing to:

 

SITERWELL ELECTRONICS CO., LIMITED 

ADDRESS: No.666 Qingfeng Road, Jiangbei District, 

Ningbo, Zhejiang Province, China. 

  Tel: 0086-574-87729581 

  Fax: 0086-574-87729581 

  E-Mail: sales @ china-siter.com 

  Http://www.china-siter.com

 

 

holes of ceiling 

G

Summary of Contents for GS592

Page 1: ...t isn t a really alarm open windows or fan the air around smoke alarm to 4 User to install this product needs to comply with all local and national electrical installation and building codes 5 This smoke alarm is designed to be used inside a single family home only In multifamily buildings each individual living unit should have its own smoke alarms Do not install in non residential buildings as t...

Page 2: ...an 93 These conditions will reduce battery life or cause a fault alarm 5 Inextremely dusty dirty or insect infested areas influence particles interfere with smoke alarm device operation Operation Testing Test the unit weekly to ensure proper operation by pressing the test button about 3 seconds later this will sound the alarm if the electronic circuitry horn and battery are working properly If no ...

Page 3: ...he unit is sensing smoke THE SOUND OF THE ALARM REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION Low Battery status An intermittent chirp accompanied by a flashing red LED indicates once every 50 seconds indicating that the battery has reached a low voltage And this is a non replaceable battery alarm so you need to replace a new smoke alarm within30 days In order to avoid noise to disturb your sleepin...

Page 4: ...rill sat night Ensure that small children hear the alarm and wake when it sounds They must wake up in order to execute the escape plan Practice allows all occupants to test your plan before an emergency You may not be able to reach your children It is important they know what to do Current studies have shown smoke alarms may not awaken all sleeping individuals and that it is the responsibility of ...

Page 5: ...idifiers Smoke heat and combustion products rise to the ceiling and spread horizontally Mounting the smoke alarm on the ceiling in the center of the room places it closest to all points in the room Ceiling mounting is preferred in ordinary residential construction Not recommend to use for MOBILE HOME For single floor plan and multiple floor plan please refer to diagram 2 and diagram 3 If alarm cou...

Page 6: ...nction WARNING To prevent injury this unit must be securely attached to the ceiling in accordance with the installation instructions Alarm must be actived by mounting the bracket before operation When the bracket is removed the alarm power is turned off SERVICE AND WARRANTY Company warrants to the original consumer Purchase each new smoke alarm to be free from defects in material and workmanship u...

Reviews: