RECOMMENDEDLOCATIONS 
FORALARMS 

 

Locate  the  first  alarm  in  the  immediate  area  of  the 
bedrooms  to  monitor  the  exit  path  as  the  bedrooms  are 
usually  farthest  from  the  exit.  If  more  than  one  sleeping 
area exists, locate additional alarms in each sleeping area. 

 

One smoke detector generally needs to be located between 
the  sleeping  area(s)  and  the  most  likely  sources  of  fire 
(living room and kitchen) 

 

Locate  additional  alarms  to  monitor  any  stairway  as 
stairways act like chimneys for smoke and heat. 

 

Locate  at  least  one  alarm  on  every  floor  level  and  every 
bedroom. 

 

An alarm needs to be installed in the room where electrical 
appliances  are  operated  (i.e.  portable  heaters  or 
humidifiers). 

 

Smoke, heat, and combustion products rise to the ceiling   
and spread horizontally. Mounting the smoke alarm on the 
ceiling  in  the  center  of  the  room  places  it  closest  to  all 
points  in  the  room.  Ceiling  mounting  is  preferred  in 
ordinary residential construction. 

 

Not recommend to use for 

MOBILE HOME

 

 

For single floor plan and multiple floor plan, please refer to 
diagram 2 and diagram 3. 

 

If alarm couldn’t be installed in the middle of the ceiling 
for some reasons, the distance which the alarm away from 
the wall corner should be beyond 50cm.(see the diagram 
4). 

 

If the length of the room or the hall is beyond 30 feet, you 
need install several alarms in the hall. 

 

When the ceiling is slanting, the alarm needs to be installed 
50cm away from the highest ceiling point in the room(see 
the diagram5).     

IMPORTANT: 

Please  keep  a  clear  space  around  all 

detectors. 

 
 
 
 
 
 
 
 
 
 

Diagram 2 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
MULTIPLE FLOOR PLA 

Diagram3 

Diagram 4 

 
 
 
 
 
 
 
 
 
 

Diagram 5 

Summary of Contents for GS592

Page 1: ...t isn t a really alarm open windows or fan the air around smoke alarm to 4 User to install this product needs to comply with all local and national electrical installation and building codes 5 This smoke alarm is designed to be used inside a single family home only In multifamily buildings each individual living unit should have its own smoke alarms Do not install in non residential buildings as t...

Page 2: ...an 93 These conditions will reduce battery life or cause a fault alarm 5 Inextremely dusty dirty or insect infested areas influence particles interfere with smoke alarm device operation Operation Testing Test the unit weekly to ensure proper operation by pressing the test button about 3 seconds later this will sound the alarm if the electronic circuitry horn and battery are working properly If no ...

Page 3: ...he unit is sensing smoke THE SOUND OF THE ALARM REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION Low Battery status An intermittent chirp accompanied by a flashing red LED indicates once every 50 seconds indicating that the battery has reached a low voltage And this is a non replaceable battery alarm so you need to replace a new smoke alarm within30 days In order to avoid noise to disturb your sleepin...

Page 4: ...rill sat night Ensure that small children hear the alarm and wake when it sounds They must wake up in order to execute the escape plan Practice allows all occupants to test your plan before an emergency You may not be able to reach your children It is important they know what to do Current studies have shown smoke alarms may not awaken all sleeping individuals and that it is the responsibility of ...

Page 5: ...idifiers Smoke heat and combustion products rise to the ceiling and spread horizontally Mounting the smoke alarm on the ceiling in the center of the room places it closest to all points in the room Ceiling mounting is preferred in ordinary residential construction Not recommend to use for MOBILE HOME For single floor plan and multiple floor plan please refer to diagram 2 and diagram 3 If alarm cou...

Page 6: ...nction WARNING To prevent injury this unit must be securely attached to the ceiling in accordance with the installation instructions Alarm must be actived by mounting the bracket before operation When the bracket is removed the alarm power is turned off SERVICE AND WARRANTY Company warrants to the original consumer Purchase each new smoke alarm to be free from defects in material and workmanship u...

Reviews: