background image

 

☆ 

SAFETY INFORMATION 

Read  and  understand  this  instruction  manual  before  operating  your  generator.  You  can  help 
prevent  accidents  by  being  familiar  with  your  generator’s  controls,  and  by  observing  safe 
operating procedure 

             

  Operator Responsibility       

Know how to stop the generator quickly in case of emergency. 

  Under stand the use of all generator controls, output receptacles, and connections. 

Do not let children operate the generator without parental supervision. 

 

Carbon Monoxide Hazards 

Exhaust  contains  poisonous  carbon  monoxide,  a  colorless  and  odorless  gas.  Breathing  exhaust 
can cause loss of consciousness and may lead to death.   
If you run the generator in an area that is confined, or even partially enclosed, the air you breathe 
could  contain  a  dangerous  amount  of  exhaust  gas.  To  keep  exhaust  gas  from  accumulating, 
provide adequate ventilation. 

Electric Shock Hazards   

The  generator  produces  enough  electric  power  to  cause  a  serious  shock  or  electrocution  if 
misused.   

Using a generator or electrical appliance in wet conditions, such as rain or snow, or near a pool or 
sprinkler system, or when your hands are wet, could result in electrocution. Keep the generator 
dry.   
If  the  generator  is  stored  outdoors,  unprotected  from  the  weather,  check  all  of  the  electrical 
components  on  the  control  panel,  before  each  use.  Moisture  or  ice  can  cause  a  malfunction  or           
short circuit in electrical components, which could result in electrocution.   
Do  not  connect  to  a  building  electrical  system  unless  a  qualified  electrician  has  installed  an 
isolation switch.   

Fire and Burn Hazards   

The exhaust system gets hot enough to ignite some materials.   

                Keep  the  generator  at  least  3  feet  (1  meter)  away  from  buildings  and  other  equipment  during 

operation. 

Do not enclose the generator in any structure. 
Keep flammable materials away from the generator. 
The  muffler  becomes  very  hot  during  operation  and  remains  hot  for  a  while  after  stopping  the 
engine. Be careful not to touch the muffler while it is hot. Let the engine cool before storing the 
generator indoors.   
Gasoline  is  extremely  flammable  and  is  explosive  under  certain  conditions.  Do  not  smoke  or 
allow flames or sparks  where the  generator is  refueled or where  gasoline is  stored. Refuel  in  a 
well-ventilated area with the engine stopped.   
Fuel vapors are extremely flammable and may ignite after the engine has started. Make sure that 
any spilled fuel has been wiped up before starting the generator. 

Summary of Contents for SPG8000

Page 1: ...G8000 PORTABLE GENERATOR INSTRUCTION MANUAL IMPORTANT Please make certain that persons who are to use this equipment thoroughly read and understand these instructions and any additional instructions provided prior to operation ...

Page 2: ...1 WARNING The generator is a potential source of electrical shock if misused DO NOT expose the generator to moisture rain or snow DO NOT let the generator get wet and do not operate it with wet hands ...

Page 3: ...S SAFETY INFORMATION 3 COMPONENT IDENTIFICATION 4 PRE OPERATION CHECK 7 STARTING THE ENGINE STOPPING THE ENGINE 8 OPERATING INSTRUCTIONS 10 MAINTENANCE 11 STORAGE 14 TROUBLE SHOOTING 16 EASY START INSTRUCTION 17 ...

Page 4: ...t could result in electrocution Keep the generator dry If the generator is stored outdoors unprotected from the weather check all of the electrical components on the control panel before each use Moisture or ice can cause a malfunction or short circuit in electrical components which could result in electrocution Do not connect to a building electrical system unless a qualified electrician has inst...

Page 5: ...4 COMPONENT IDENTIFICATION ...

Page 6: ...ART position when the engine is running to prevent damage of starting motor Recoil Starter To start the engine pull the starter grip lightly until resistance is felt then pull briskly WARNING Do not allow the starter grip to snap back against the engine Return it gently to prevent damage to the starter Fuel Valve Lever The fuel valve is located between the fuel tank and carburetor When the valve l...

Page 7: ...inding Post The DC 12V binding post may only be used for charging 12 volt automotive type batteries DC Circuit Protector The DC circuit protector automatically shuts off the DC battery charging circuit when the DC charging circuit is overloaded when there is a problem with the battery or when the connections between the battery and the generator are improper Oil Alert System The Oil Alert system i...

Page 8: ...t protector switches OFF automatically check that the appliance is working properly and does not exceed the rated load capacity of the circuit before resetting the AC circuit protector ON PRE OPERATION CHECK Engine Oil WARNING Engine oil is a major factor affecting engine performance and service life Non detergent and 2 stroke engine oils will damage the engine and are not recommended Check the oi...

Page 9: ...e burned or seriously injured when refueling Stop engine and keep heat sparks and flame away Refuel only outdoors Wipe up spills immediately Use unleaded gasoline with a pump octane rating of 86 or higher This engine is certified to operate on unleaded gasoline Unleaded gasoline produces fewer engine and spark plug deposits and extends exhaust system life Never use stale or contaminated gasoline o...

Page 10: ...de some medical equipment personal computers and some inverters that sense peak and RMS voltage values Consult the precision equipment vendor before relying on any portable generator to provide power to such equipment Connection Alternating Current AC Be sure all electric devices including the lines and plug connections are in good condition before connection to the generator Be sure any electric ...

Page 11: ... company or a qualified electrician Connection Notes Avoid connecting the genetor to commercial power outlets This is a single phase generator only Avoid connecting the generator in parallel with any other generator Ground System The portable generators have a system ground that connects generator frame components to the ground terminals in the AC output receptacles The system ground is not connec...

Page 12: ...lso foul the spark plug and cause hard starting Operation at an altitude that differs from that at which this engine was certified for extended periods of time may increase emissions High altitude performance can be improved by specific modifications to the carburetor If you always operate your generator at altitudes above 5 000 feet 1 500 meters have your dealer perform this carburetor modificati...

Page 13: ...based on the assumption that your machine will be used for its designed purpose Sustained high load or high temperature operation or use in unusually wet or dusty conditions will require more frequent service 1 Service more frequently when used in dusty areas 2 For commercial use log hours of operation to determine proper maintenance intervals Engine Oil Change Drain the oil while the engine is wa...

Page 14: ... or wash in nonflammable or high flashpoint solvent Allow the air cleaner element to dry thoroughly 3 Soak the air cleaner element in clean engine oil and squeeze out the excess oil The engine will smoke during initial startup if too much oil is left in the air cleaner element Reinstall the air cleaner element and the cover Fuel Sediment Cup Cleaning The sediment cup prevents dirt or water which m...

Page 15: ... spark plug washer is in good condition and thread the spark plug in by hand to prevent cross threading 7 After the spark plug is seated tighten with a spark plug wrench to compress the washer If installing a new spark plug tighten 1 2 turn after the spark plug seats to compress the washer If reinstalling a used spark plug tighten 1 8 1 4 turn after the spark plug seats to compress the washer WARN...

Page 16: ...g Use gasoline conditioners that are formulated to extend storage life Contact your authorized Dexin generator dealer for conditioner recommendations 1 Drain the carburetor by loosening the drain screw Drain the gasoline into a suitable container WARNING Gasoline is extremely flammable and is explosive under certain conditions Perform thistask in awell ventilated area with the engine stopped Do no...

Page 17: ...ed oil Is the spark plug in good condition Readjust gap and dry the spark plug Replace it if necessary Is the fuel reaching the carburetor Clean the fuel sediment cup No electricity at the AC receptacles Is the AC circuit breaker ON Turn the AC circuit breaker ON Check the electrical appliance or equipment for any defects Replace the electrical appliance or equipment Take the electrical appliance ...

Page 18: ...4 Turn fuel control valve to ON position 5 Move air hindrance level CHOKE to the left Tune Key to Start or pull Recoil Start Rope complete easy pulls until start 6 After start move Choke level to the right slowly If engine dies complete the above procedures If Choke is left on and engine dies your spark plug is known fouled and will need to be cleaned 7 Before you apply any plugs into receptacles ...

Reviews: