Stopping the Engine   

In an emergency:

   

To stop the engine in an emergency, move the engine switch to the OFF position.   

In normal use: 

 

1. Turn the AC circuit breaker to the OFF position.     
2. Turn the engine switch to the OFF position.   
3. Turn the fuel valve lever to the OFF position.   

OPERATING INSTRUCTIONS 

Connections to a Building Electrical System   

Connections  for  standby  power  to  a  building  electrical  system  must  be  made  by  a  qualified 
electrician. The connection must isolate the generator power from utility power, and must comply 
with  all  applicable  laws  and  electrical  codes.  A  transfer  switch,  which  isolates  generator  power 
from utility power, is prerequisite.   

WARNING: 

tility  company  workers  or  others  who  contact  the  lines  during  a  power  outage,  and  the  generator 
may  explode,  burn,  or  cause  fires  when  utility  power  is  restImproper  connections  to  a  building 
electrical system can allow electrical current from the generator to back feed into the utility lines. 
Such back feed may electrocute uored. Consult the utility company or a qualified electrician.   
 

Connection Notes 

  Avoid connecting the genetor to commercial power outlets

This is a single phase generator only

 

                  Avoid connecting the generator in parallel with any other generator

 

Ground System   

The  portable  generators  have  a  system  ground  that  connects  generator  frame  components  to  the 
ground terminals in the AC output receptacles. The system ground is not connected to the AC neutral 
wire.   
Make  sure  you  connect  a  proper  ground  (earth)  to  the  generator. 

You  should  use  the  ground 

terminal on the front panel of the generator and a stake at the end of uncovered copper ground 
wire driven into soil.This completes a safe natural ground circuit. 

  Ground(earth) Lead 
  Diameter: 
          0.12mm(0.005in) per (ampere) Amp 

 

EXAMPLE: 

      10(Ampere) Amps

1.2mm

0.05in

 

AC Applications   

B

efore connecting an appliance or power cord to the generator:   

Make sure that it is in good working order. Faulty appliances or power cords can create a potential for 
electrical shock.   
If  an  appliance  begins  to  operate  abnormally,  becomes  sluggish  or  stops  suddenly,  turn  it  off 
immediately. Disconnect the appliance, and determine whether the problem is the appliance, or if the 
rated load capacity of the generator has been exceeded.   

Summary of Contents for SPG8000

Page 1: ...G8000 PORTABLE GENERATOR INSTRUCTION MANUAL IMPORTANT Please make certain that persons who are to use this equipment thoroughly read and understand these instructions and any additional instructions provided prior to operation ...

Page 2: ...1 WARNING The generator is a potential source of electrical shock if misused DO NOT expose the generator to moisture rain or snow DO NOT let the generator get wet and do not operate it with wet hands ...

Page 3: ...S SAFETY INFORMATION 3 COMPONENT IDENTIFICATION 4 PRE OPERATION CHECK 7 STARTING THE ENGINE STOPPING THE ENGINE 8 OPERATING INSTRUCTIONS 10 MAINTENANCE 11 STORAGE 14 TROUBLE SHOOTING 16 EASY START INSTRUCTION 17 ...

Page 4: ...t could result in electrocution Keep the generator dry If the generator is stored outdoors unprotected from the weather check all of the electrical components on the control panel before each use Moisture or ice can cause a malfunction or short circuit in electrical components which could result in electrocution Do not connect to a building electrical system unless a qualified electrician has inst...

Page 5: ...4 COMPONENT IDENTIFICATION ...

Page 6: ...ART position when the engine is running to prevent damage of starting motor Recoil Starter To start the engine pull the starter grip lightly until resistance is felt then pull briskly WARNING Do not allow the starter grip to snap back against the engine Return it gently to prevent damage to the starter Fuel Valve Lever The fuel valve is located between the fuel tank and carburetor When the valve l...

Page 7: ...inding Post The DC 12V binding post may only be used for charging 12 volt automotive type batteries DC Circuit Protector The DC circuit protector automatically shuts off the DC battery charging circuit when the DC charging circuit is overloaded when there is a problem with the battery or when the connections between the battery and the generator are improper Oil Alert System The Oil Alert system i...

Page 8: ...t protector switches OFF automatically check that the appliance is working properly and does not exceed the rated load capacity of the circuit before resetting the AC circuit protector ON PRE OPERATION CHECK Engine Oil WARNING Engine oil is a major factor affecting engine performance and service life Non detergent and 2 stroke engine oils will damage the engine and are not recommended Check the oi...

Page 9: ...e burned or seriously injured when refueling Stop engine and keep heat sparks and flame away Refuel only outdoors Wipe up spills immediately Use unleaded gasoline with a pump octane rating of 86 or higher This engine is certified to operate on unleaded gasoline Unleaded gasoline produces fewer engine and spark plug deposits and extends exhaust system life Never use stale or contaminated gasoline o...

Page 10: ...de some medical equipment personal computers and some inverters that sense peak and RMS voltage values Consult the precision equipment vendor before relying on any portable generator to provide power to such equipment Connection Alternating Current AC Be sure all electric devices including the lines and plug connections are in good condition before connection to the generator Be sure any electric ...

Page 11: ... company or a qualified electrician Connection Notes Avoid connecting the genetor to commercial power outlets This is a single phase generator only Avoid connecting the generator in parallel with any other generator Ground System The portable generators have a system ground that connects generator frame components to the ground terminals in the AC output receptacles The system ground is not connec...

Page 12: ...lso foul the spark plug and cause hard starting Operation at an altitude that differs from that at which this engine was certified for extended periods of time may increase emissions High altitude performance can be improved by specific modifications to the carburetor If you always operate your generator at altitudes above 5 000 feet 1 500 meters have your dealer perform this carburetor modificati...

Page 13: ...based on the assumption that your machine will be used for its designed purpose Sustained high load or high temperature operation or use in unusually wet or dusty conditions will require more frequent service 1 Service more frequently when used in dusty areas 2 For commercial use log hours of operation to determine proper maintenance intervals Engine Oil Change Drain the oil while the engine is wa...

Page 14: ... or wash in nonflammable or high flashpoint solvent Allow the air cleaner element to dry thoroughly 3 Soak the air cleaner element in clean engine oil and squeeze out the excess oil The engine will smoke during initial startup if too much oil is left in the air cleaner element Reinstall the air cleaner element and the cover Fuel Sediment Cup Cleaning The sediment cup prevents dirt or water which m...

Page 15: ... spark plug washer is in good condition and thread the spark plug in by hand to prevent cross threading 7 After the spark plug is seated tighten with a spark plug wrench to compress the washer If installing a new spark plug tighten 1 2 turn after the spark plug seats to compress the washer If reinstalling a used spark plug tighten 1 8 1 4 turn after the spark plug seats to compress the washer WARN...

Page 16: ...g Use gasoline conditioners that are formulated to extend storage life Contact your authorized Dexin generator dealer for conditioner recommendations 1 Drain the carburetor by loosening the drain screw Drain the gasoline into a suitable container WARNING Gasoline is extremely flammable and is explosive under certain conditions Perform thistask in awell ventilated area with the engine stopped Do no...

Page 17: ...ed oil Is the spark plug in good condition Readjust gap and dry the spark plug Replace it if necessary Is the fuel reaching the carburetor Clean the fuel sediment cup No electricity at the AC receptacles Is the AC circuit breaker ON Turn the AC circuit breaker ON Check the electrical appliance or equipment for any defects Replace the electrical appliance or equipment Take the electrical appliance ...

Page 18: ...4 Turn fuel control valve to ON position 5 Move air hindrance level CHOKE to the left Tune Key to Start or pull Recoil Start Rope complete easy pulls until start 6 After start move Choke level to the right slowly If engine dies complete the above procedures If Choke is left on and engine dies your spark plug is known fouled and will need to be cleaned 7 Before you apply any plugs into receptacles ...

Reviews: