background image

 

BA_ST_DSG-D_EN_36-21.docx

 

9

 

 

Digital Angle Display

 

2.6.1

 

Calibrate indicator to the fence 

Pressing the 

 key will set the display to the value 0.00. This can be done 

at any angle setting of the fence.  

To return the display to its original position (0.00 at 0° resp. 90°), swing 
the fence against the fence screws (refer to 

 Figure 2) and then press  

 key. 

2.6.2

 

Battery change 

The power supply for the position indicator is provided by two 1.5 Volt 
batteries type Micro "AAA", which are accessible by loosening the two 
screws of the battery case on the rear of the unit. When the battery 
symbol (see 

 Figure 10) appears in the display, the battery should be 

replaced as soon as possible. Please ensure that the polarity is correct 
(see 

 Figure 11)

 

 
 

 

Figure 10: Digital angle display 

 

 

Figure 11: Battery case (rear) 

 

Since the current angular position is not saved when the battery is changed, the indicator 
must be recalibrated to the fence afterwards (as described in section 

 2.6.1).

 

 

 

Fire, explosion and burn hazard!

 Never recharge batteries or expose them to temperatures  

above 85° C. Please dispose of the used batteries properly.

 

 

2.6.3

 

Further documentation 

Further documentation and manuals for the digital display can be found on the manufacturer's website: 

 

https://www.siko-global.com/en-de/products/magline-magnetic-linear-and-angular-measurement/electronic-displays/ma504-1

 

 

3

 

Wall Bracket  

The wall bracket for the DSG-D offers 
a practical way to store the fence 
within easy reach when not in use.  
It is already included in the scope of 
delivery.  
 
The two clamping pins shown in  

 Figure 12 are located on the un-

derside of the fence. They can be 
used for quick and tool-free attach-
ment of the device to the wall 
bracket. 
 

 

Figure 12: DSG-D wall bracket 

 

P

 

Wall bracket

Clamping pins

Summary of Contents for DSG-D

Page 1: ...berg Kaserne Binger Str 28 Halle 120 DE 72488 Sigmaringen Tel 49 07571 755 0 E Mail info hokubema panhans de Web https hokubema panhans de Operation Manual DSG D Double Sided Mitre Fence For use on sliding table saws according to the DIN EN 1870 18 2011 08 standard Type DSG D ...

Page 2: ...re 2 Adjusting the DSG D 2 5 Figure 3 Adjusting the DSG D 3 5 Figure 4 Adjusting the DSG D 4 6 Figure 5 DSG D adjustment example 6 Figure 6 Clamping screw for flap rail 6 Figure 7 Set factor by scale 7 Figure 8 Angles for wrong mitres 7 Figure 9 Length compensation via table 7 Figure 10 Digital angle display 9 Figure 11 Battery case rear 9 Figure 12 DSG D wall bracket 9 Revisions Revision Editor C...

Page 3: ... at any angle from 0 90 Automatic length compensation for preferred angles 5 10 15 22 5 30 45 60 67 5 An imprinted scale simplifies the production of incorrect mitres Easy handling and quick mounting on the trolley of the saw Angle length measurement adjustable via digital display The leg length available for cutting is maximum 1375 mm Including wooden support block and wall bracket Bounce free mo...

Page 4: ...he DSG D on the edging table 1 Move eccentric lever to handle up position 2 Place the fence on the edging table 3 Check whether the press on screws are in contact with the edging table and re adjust if necessary 1 Loosen the two M8 screws This ensures that the fence rests correctly on the edging table 2 Clamp the fence by tightening the eccentric lever 3 Retighten the two M8 screws Press on screw ...

Page 5: ...ich is approximately parallel to the saw blade CAUTION Make sure that the support block is in contact with the profile Figure 1 Adjusting the DSG D 1 Figure 2 Adjusting the DSG D 2 6 Carefully push the fence with the material up to the saw blade Figure 3 7 At this position retighten the M8 clamping screws first on one side Then swivel the fence so that the two clamping screws on the other side can...

Page 6: ...ure 4 Adjusting the DSG D 4 Because the fence scale has different markings for reading the length it is possible to set the exact length to the cutting line at certain angles Example If for example the fence is set to an angle of 22 5 and the length dimension is set so that the marking line on the scale below the 22 5 is congruent with any measure for example 350 mm on the scale of the profile thi...

Page 7: ... right refer Figure 8 The corresponding sides for the narrow and wide workpiece are also shown graphically on the turntable plate Figure 7 Set factor by scale Figure 8 Angles for wrong mitres Table for length compensation on the double sided mitre fence Using the table refer to section 2 5 the length compensation dimension can be set in addition to the angles printed on the scale of the mitre fenc...

Page 8: ... 3 58 5 23 3 10 18 5 34 42 5 59 21 9 10 5 19 3 34 5 42 6 59 5 20 5 11 20 0 35 42 8 60 18 9 11 5 20 8 35 5 42 9 60 5 17 4 12 21 6 36 43 1 61 15 7 12 5 22 3 36 5 43 2 61 5 13 9 13 23 0 37 43 3 62 12 1 13 5 23 7 38 5 43 4 62 5 10 2 14 24 4 39 43 4 63 8 1 14 5 25 1 39 5 43 5 63 5 6 0 15 25 8 40 43 5 64 3 8 15 5 26 5 40 5 43 4 64 5 1 4 16 27 1 41 43 4 65 1 1 16 5 27 8 41 5 43 3 65 5 3 7 17 28 4 42 43 2...

Page 9: ...ery case rear Since the current angular position is not saved when the battery is changed the indicator must be recalibrated to the fence afterwards as described in section 2 6 1 Fire explosion and burn hazard Never recharge batteries or expose them to temperatures above 85 C Please dispose of the used batteries properly 2 6 3 Further documentation Further documentation and manuals for the digital...

Reviews: