TRANSPORTING AND STORAGE
A few guidelines need to be followed before transporting the water pump. Below is a list of
instructions to be followed during transportation.
●
When transporting the pump, turn the fuel valve off and keep the pump on a level surface
to prevent fuel spillage.
●
Secure the pump unit to a fixed object when transporting to prevent the pump from
bouncing around Continuous bouncing around can damage the pumps internals.
Before storing the pump for long periods of time, please follow the guidelines below.
●
Clean the pump interior before stopping the pump. Remove the pump drain plug and
empty all fluids from the pump. Leaving fluid in the pump will cause rapid corrosion to
the impeller.
●
Turn the fuel valve to the “Off” position and empty all of the fuel out of the gas tank.
Note: While dealing with diesel fuel, do not smoke or allow flames to come near the fuel as
accidents may occur. Failing to do so will lead to serious injuries or death.
●
Change the engine oil.
●
Remove the cold start oil fill plug and pour about a tablespoon of oil into the cylinder.
Crank the engine several times.
●
Pull the starter rope until resistance is felt. Doing this will put the cylinder on the
compression stroke; where both intake and exhaust valves are closed. Having these two
valves closed will prevent moisture from getting into the combustion chamber and
causing corrosion.
●
Cover the engine and pump and store in a dry place.