10
6.2 AL
2
version (with display)
DISPLAY MESSAGES – Start up:
No Power (Connect to power supply)
Identification of the software revision
Working days count down (lamp life 1 year)
DISPLAY INFORMATIONS – Working hours:
Press
(
◄
┘
)
for less than 1 sec to show the lamp working hours:
Working days count down
System Total Working Days
DISPLAY ALARMS – Troubleshooting:
AL1:
Indicates the end of lamp life(count-down timer shows 0 days). In such case replace the lamp
and restart the working days count down.
To restart the working days count down replace the lamp and press and hold for less than 5 seconds the
(
◄
┘
)
button. The value of the days-meter will start to flash. Within 5 sec press again the button to
confirm the days-meter reset.
ATTENTION
: Do not replace the lamp with powered panel!!!
Press and hold for more than 9 seconds the
(
◄
┘
)
button to silence the alarm for 7 days (max 4 times).
Working days count down (lamp exhaust)
Alarm + Buzzer
Working days count
down (restarted)
01.0
365
365
012
000
AL1
AL1
365
Press Ok < 1 sec
(
◄
┘
)
Press and Hold > 9 sec.
(
◄
┘
)
to stop the buzzer
Keep pressed for less than
5 sec. (◄┘).
The value of the days-
meter will start to flash.
Within 5 sec press again
the button to confirm the
days-meter reset.
Alarm AL1
Event