16.5 Connection to the pipe network (see picture)
The intakes for the connection to the suction pipes network and to the pipes exhausting the air outside
can be assembled either on the right or left side of the unit.
Using the eccentric extension 80/63,
the sleeve and the metal clamps de
-
livered with the vacuum cleaner, con
-
nect the unit to the air suction pipe.
Using the sleeve and the metal clamps
delivered with vacuum cleaner, con
-
nect the unit to the exhaust pipe.
Assemble a silencer on the exhaust
pipe; position the silencer near the ex
-
haust grid.
Exhaust grid
Silencer
Suction pipe
Exhaust pipe
A
B
C
Using the sleeve to connect the junction of the central air vent, identified with the letter (B), the area of
air exhaust hose
N.B. Diameter of exhaust pipe for lengths up to 6m:
63 mm
Diameter of exhaust pipe for lengths from 6m to 8m:
80 mm
Diameter of the exhaust pipe for lengths from 8m to 10m: 100 mm
It is not recommended to use an exhaust pipe with a length of over 10m, because it could
prove damaging the central vacuum cleaner.