sisel ENDA ET4430 Manual Download Page 5

ET4430-Modbus-EN-01-190116

SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.

Şerifali Mah. 

 Y.Dudullu  34775

ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx.    Fax : +90 216 365 74 01
url : www.enda.com.tr

Barbaros Cad. No:18

 1/

3

ENDA

TM

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

Word

0000d   (0000h)

400

0

600

4

2

40

100

20

0

0

0

400

500

0

600

600

100

500

0

2

2

5

0

0

20

0

0

0

0

0

1

3

10

0

0

0

0

20

20

000

1

d   (000

1

h)

000

2

d   (000

2

h)

000

3

d   (000

3

h)

000

4

d   (000

4

h)

000

5

d   (000

5

h)

000

6

d   (000

6

h)

000

7

d   (000

7

h)

000

8

d   (000

8

h)

000

9

d   (000

9

h)

00

10

d   (000

A

h)

00

11

d   (000

B

h)

00

12

d   (000

C

h)

00

13

d   (000

D

h)

00

14

d   (000

E

h)

00

15

d   (000

F

h)

00

16

d   (00

1

0h)

00

17

d   (00

11

h)

00

18

d   (00

12

h)

00

19

d   (00

13

h)

00

20

d   (00

14

h)

00

22

d   (00

16

h)

00

21

d   (00

15

h)

00

23

d   (00

17

h)

00

24

d   (00

18

h)

00

25

d   (00

19

h)

00

26

d   (00

1A

h)

00

27

d   (00

1B

h)

00

28

d   (00

1C

h)

00

29

d   (00

1D

h)

00

30

d   (00

1E

h)

00

31

d   (00

1F

h)

00

32

d   (00

20

h)

00

33

d   (00

21

h)

00

34

d   (00

22

h)

00

35

d   (00

23

h)

00

36

d   (00

24

h)

00

37

d   (00

25

h)

00

38

d   (00

26

h)

H1

H0

H2

H3

H4

H5

H6

H7

H8

H9

H10

H11

H12

H13

H14

H15

H16
H17

H18

H19

H20

H21

H23

H22

H24

H25

H26
H27

H28

H29

H30

H31

H32

H33
H34

H35

H36

H37

H38

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

C1.SE.

C2.SE.

C.S.Lo.

C.S.Hi.

C. Pb.

C.HyS..

C. ti.

C. td.

C. Ct.

C.C.p.S.

C.E.p.S.

S.St.S.

A1.SE.

A1.S.l.

A1.S.H.

A1.Pb.

A1.Hy.

A1.ti.

A1.td.

A1.Ct.

A1.P.S.

A1.E.P.

A1.tP.

A2.SE.

A2.S.L.

A2.S.H.

A2.Hy.

A2.tP.

inP.t.

d.Adr.

baud.

FLtr.

C.o.SE..

A.o.Lo..

A.o.Hi..

oFFs.

----

Word

50

00

39

d   (00

27

h)

H39

m.SEt

R/W

R/W

R/W

R/W

R/W

R/W

1.1 Memory Map for Holding Registers

Analog output minimum out percentage

C

o

n

tr

o

O

u

tp

u

P

a

ra

m

e

te

rs

A

1

 O

u

tp

u

P

a

ra

m

e

te

rs

C

o

n

fi

g

u

ra

ti

o

n

 P

a

ra

m

e

te

rs

A

O

ut

pu

t P

ar

am

et

er

s

Control output, temperature setpoint value

Alarm1 output temperature setpoint value

Control output, time period setpoint value (Adjustable between 1 and 125 second)

Control output, soft start value

Control output, 2nd temperature setpoint value

Alarm1 output type selection

  (

Values can be given from 0 to 4

) (0 = 

Independent alarm

,

1 = 

Deviation alarm

, 2 = Band alarm, 3 = 

Active alarm after in band time

,

4 = 

Alarm1 output, cooling control selection

 )

 

Alarm2 output type selection

  (

Values can be given from 0 to 3

) (0 = 

Independent alarm

,

1 = 

Deviation alarm

, 2 = Band alarm, 3 = 

Active alarm after in band time

)

ModBus device address (Adjustable between 1 and 247)

Modbus communication speed (Baudrate) (0 = Modbus cancel, 1 = 2400 bps, 2 = 4800 bps, 
3 = 9600 bps, 4 =19200 bps, 5 = 38400 bps)

Analog output maximum out percentage

Offset value

Function control parameter.
( 23040d ( 5A00h ) self tune stops when this value is entered )
( 23041d ( 5A01h ) self tune starts when this value is entered )
( 23042d ( 5A02h ) returns to factory defaults when this value is entered)

Control output, minimum setpoint value

Alarm1 output minimum setpoint value limit

Control output, maximum setpoint value

Alarm1 output maximum setpoint value limit

Control output, proportional band setpoint value

 (Adjustable between 0

.0

%

 and 100

.0

%

)

Alarm1 output proportional band set value 

(Adjustable between 0

.0

%

 and 100

.0

%

)

Control output, set value power ratio

 (Adjustable between 0% and 100%)

Control output, hysteresis value

 

(Adjustable between 

1

 and 50 

°C 

or

 °F

)

Alarm1 output hysteresis value

 

(Adjustable between 

1

 and 50 

°C 

or

 °F

)

Control output, integral time

 

(Adjustable between 

0.1 

 and 

100.0 

minute

)

Control output, derivative time

 

(Adjustable between 

0.01 

 and 

10.00 

minute

)

Input selection number (0 = 

 1 = 

 2 = 

3 = 

 4 = 

 5 = 

 6 = 

 7 = 

8 = 

 9 = 

 10= 

 11 = 

PT100 Decimal,

Pt100 Non-decimal,

J Decimal,

J Non-decimal, 

K Decimal, 

K Non-decimal, 

L Decimal, 

L Non-decimal,

T Decimal, 

T Non-decimal,

S Non-decimal,

R Non-decimal

Alarm1 output, integral time

 

(Adjustable between 

0.1 

 and 

100.0 

minute

)

Alarm1 output, derivative time

 

(Adjustable between 

0.01 

 and 

10.00 

minute

)

Alarm1 output, time period setpoint value (Adjustable between 1 and 125 second)

Alarm1 output, set value power ratio

 (Adjustable between 0% and 100%)

Alarm1 output, set value power ratio in case of sensor failure 

(Adjustable between %0 

and

 %100)

Alarm2 output, temperature setpoint value

Alarm2 output minimum setpoint value limit

Alarm2 output maximum setpoint value limit

Alarm2 output, hysteresis value

 

(Adjustable between 

1

 and 50 

°C 

or

 °F

)

Reserverd

Digital filter coefficient

 (

Adjustable between 

and

 200

,

 1 

= filter is disable

)

Control output, selection value ( 

0 =

 C/A2 Control output selection, 

1 =

 SSR Output selection )

ENDA ET4430 PID 

TEMPERATURE

 CONTROLLER

 

    MODBUS PROTOCOL ADDRESS MAP

Control output energy percentage in case of sensor error (can be set between 0% to 100%)

Reserverd

----
----

Manual control output percentage (can be adjusted between 0% and 100%)

Holding Register 

A

dres

s

De

c

imal    (Hex)      

Parameter

Number

      

Data

Type

Default

Value

Parame

ter

Name

Read

 /

 Write

Permission

Paramet

er Description

Summary of Contents for ENDA ET4430

Page 1: ...screw terminal connections 1 5mm EN 61326 1 2013 Performance criterion B satisfied for EN 61000 4 3 standard EEPROM minimum 10 years Max 100 Ohm EN 61010 1 2010 Pollution degree 2 overvoltage category...

Page 2: ...pplement to cables Connect the thermocouple cables to the right places at the input terminal For resistance PT100 Sensor In order to using 2 wire resistance sensors PT100 8th and 9th terminals must be...

Page 3: ...ent Alarm A1 tp indE Deviation Alarm A1 tp dE Band Alarm A1 tp bAnd SV CONT output set value ASV Alarm output set value ASV min 300 ASV maks 300 ASV min beginning of scale ASV max end of scale ASV min...

Page 4: ...m bAnd Band alarm bAn i Band with inhibition A2s t Status selection for Alarm2 Output If Hi is selected A2 output is above the Alarm2 set value ON If lo is selected A2 Output is above the Alarm2 set v...

Page 5: ...rm 2 Band alarm 3 Active alarm after in band time ModBus device address Adjustable between 1 and 247 Modbus communication speed Baudrate 0 Modbus cancel 1 2400 bps 2 4800 bps 3 9600 bps 4 19200 bps 5...

Page 6: ...d 002Dh 0047d 002Fh 0048d 0030h 0049d 0031h 0050d 0032h 0051d 0033h 0052d 0034h 0041d 0029h 0042d 002Ah H41 H43 H44 H45 H47 H46 H48 H49 H50 H51 H52 H40 H42 R W R W R W R W R W R W R W R W R W R W R W...

Page 7: ...the query is not an allowable action for the slave If a Poll Program Complete command was issued this code indicates that no program function preceded it The data address received in the query is not...

Reviews: