10.

功能鍵:按此按鍵可進入系統參數設定功

能。

11.

手動鍵:用手動方式觸動開關,以進入下

一段車縫工程

12.

自動鍵:當車縫針數計數到達設定值時,

系統自動進入下一段車縫工程。

13.

馬達轉動鍵:按此按鍵時馬達會轉動,可

用於送入或退出鬆緊帶。

      P.S.:

參數

9

設定值為

0

:馬達轉動時,可

退出鬆緊帶。參數

9

設定值為

1

:馬達轉

動時,可送入鬆緊帶。

14.

馬達停止鍵:按此按鍵系統會進入馬達停

止轉動模式。

     P.S.:

在馬達停止轉動模式,按功能鍵可進

入測量縫紉機轉速功能。

15.

切刀鍵:按此鍵可在車縫段數間,執行或

取消切刀動作。

16.

增加鍵:增加設定數值。

17.

減少鍵:減少設定數值。

18.

載入針數鍵:可在車縫設定模式,將計數

器所顯示的車縫針數,載入到該車縫段的
針數設定值,原有的針數設定值將會被刪
除。

10. Function key: Press this key to enter 
      the parameter setting function.
11. Manual key: Turn on the switch 
      manually to enter the next section.
12. Automation key: When the number of 
      stitches is completed, the system 
      enters the next section automatically.
13. Motor operating key: Press this key to 
      start the motor, and the elastic tape 
      can be fed or withdrawn.
      P.S.: parameter 9, setting value 0: 
              When the motor operates, the 
              elastic tape is withdrawn.
              parameter 9, setting value 1: 
              When the motor operates, the 
              elastic tape is fed.
14. Motor stopping key: Press this key to 
      Stop the motor.
      P.S.: When the motor stops operating, 
               press this key to enter the 
               function of measuring the 
               rotational speed of the sewing 
               machine.
15. Trimmer key: Press this key to execute 
      or cancel the thread cutting during the 
      sections.
16. Increase key: Increase the setting 
      value.
17. Decrease key: Decrease the setting 
      value.
18. Stitch loading key: In the sewing 
      setting mode, the number of stitches 
      shown on the counter can be loaded 
      to the stitch setting value of the 
      section, and the original stitch setting 
      Value is cancelled.

1 2

3

4

5

6

7

15

14

13

12

11

10

9

8

16

17
18

P18

Introduction

Summary of Contents for 700KS-LFD6-K1

Page 1: ...700KS LFD6 K1 INSTRUCTION BOOK PARTS LIST...

Page 2: ......

Page 3: ...CES INSTALLATION INSTRUCTION 8 TIP CODE LIST AND ERROR CODE LIST 9 COMBINATION 11 POWER WIRING DIAGRAM 12 WIRING DIAGRAM 13 D6 D6 DEVICE ADJUSTMENTS 14 THE ILLUSTRATION OF THE CONTROL PANEL 17 THE ILL...

Page 4: ...where there is risk to cause any fire or explosion 3 Guard against electric shock Avoid body contact with earthed or grounded surfaces e g Pipes radiators ranges refrigerators 4 Keep children away Do...

Page 5: ...f any accessory or attachment other than those recommended in this instruction manual may present a risk of personal injury 12 Have your tool repaired by a qualified person Repairs should only be carr...

Page 6: ...using this machine please ascertain that it conforms with safety standards and regulations of your country 4 When the machine is ready for operation all the safety equipments must be ready Operate thi...

Page 7: ...parts for replacement 11 Routine maintenance and service must be performed by well trained persons or qualified technicians 12 Maintain and check the electronic parts must be done by qualified electr...

Page 8: ...essary No responsibility will our company take for damages caused by any modification or conversion of this machine without permission 19 Two safety warning signs are applied as warning signs 1 For th...

Page 9: ...he machine when placing or lifting the machine head to avoid possible physical injuries f Please turn off the power before tilting the machine head to avoid possible accidents due to abrupt start of t...

Page 10: ...Never use the machine when the local voltage type is different from the marked voltage on the nametag attached on the machine 6 Confirm that the rotating direction of the machine pulley is correct War...

Page 11: ...INSTALLATION INSTRUCTION 1 LF D6 LF D6 Control Box 2 Switch 3 Top Under Blow Control Valve 4 Tape Cutting Switch 5 Control Box 6 UT54K UT54K Adjusting Filter 7 Thread Suction Adjusting Vave 8 Air Suct...

Page 12: ...0 V power source Green Yellow wire must do the grounding 220V 380V Caution If the power source does not have the neutral point then this 1 220 V servo motor is not suitable for this connection Please...

Page 13: ...d balance when use a 1 220 V motor used on a 3 220 V power source See the following figure for the load balance N PE G G G Grounding system 1 220V Motor 1 220V Motor 1 220V Motor L1 L1 L1 L2 Neutral 3...

Page 14: ...COMBINATION 1 Contrl Box 1 3 Contrl Box 3 Pedal Switch P11...

Page 15: ...trimmer C Sending the tape and blowing D The thread pull off function E The suction function P12 Introduction Electronic Controller Section Display Section Exchange Switch Five phase Stepping Motor Si...

Page 16: ...P Airsupplysource WIRING DIAGRAM P13...

Page 17: ...screw Sm532 can be adjusted up and down and keep the gap of presser foot and D6cutter device within 1 0 2 0mm SM532 2 1 SM441 SM514 2 FD621 SM514 3 SM514 SM441 2 Adjust the left and right direction of...

Page 18: ...fe FD616 would be larger Turn toward the direction B the occlusion degree would be smaller Please adjust the occlusion to 1 0 2 0mm The occlusion when manufactured According to the sewing requirements...

Page 19: ...than 1 inch have it align to the right red line As the diagram B for using the elastic belt over 1 inch have it align to the left red line As the diagram C 4 A 1 B 1 C A Diagram A Short Roller Red Li...

Page 20: ...5 indicates 6 5mm 5 Stitch setting Set the number of stitches that is required for each section The setting values are 0 999 stitches 6 Circulation setting It can memorize 10 sets of setting values of...

Page 21: ...9 setting value 1 When the motor operates the elastic tape is fed 14 Motor stopping key Press this key to Stop the motor P S When the motor stops operating press this key to enter the function of meas...

Page 22: ...is 800 ms The accomplishment of the trimmer the needle numbers which need to sewing the rest elastic belt The setting value is 0 99 0 It indicates that the needful needle numbers is 0 99 It indicates...

Page 23: ...m blow device Set the timing of the trimmer closure The setting value is 5 50 5 It indicates that the timing of the trimmer closure is 50ms 50 It indicates that the timing of the trimmer closure is 50...

Page 24: ...r pulling back the tape after sewing starts The setting values are 0 99 0 indicates that the tape is pulled back immediately after sewing starts 99 indicates that the tape is pulled back after the 99t...

Page 25: ...section selecting key 2 section 2 the setting ends press the cancel key 2 25 section 2 tape feeding length 25 ON sewing mode indicator light ON Section Tape feeding length Stitch Trimmer 1 25 OFF set...

Page 26: ...N sewing mode indicator light ON press the preparation key save the setting value Section Tape feeding length Stitch Trimmer 1 25 100 Section Tape feeding length Stitch Trimmer 1 25 100 2 35 100 3 40...

Page 27: ...00 Auto 3 25 120 4 20 OFF setting mode indicator light OFF 2 section 2 press the trimmer key press the manual 5 section 5 press the cancel key 5 end the section 5 setting ON sewing mode indicator ligh...

Page 28: ...etting value 30mm set that the length of the tape pulled back is 30mm 3 select parameter 3 press the function key OFF setting mode indicator light OFF ON sewing mode indicator light ON press the prepa...

Page 29: ...rd Position Five phase Stepping Motor Driver I O I O Panel Solenoid Valve Fan Power Supplier Power Switch LCM LCM Contrast Adjustment Knob Suggestion Adjust the resistance value to the middle value Bu...

Page 30: ...1 2 1 The control panel is blank 2 The stepping motor driver is no signal P27...

Page 31: ...3 3 The setting value of the stepping motor driver P28 Introduction...

Page 32: ...s touched and cannot be reverted 5 The panel displays E02 It indicates that EEPROM on the control panel is abnormal and cannot work regularly Solution Substitute another new control panel FD683 6 The...

Page 33: ...7 E04 7 The panel displays E04 It indicates that the coil detector is abnormal and cannot work regularly P30 Introduction...

Page 34: ...CM display panel section display buzzer and solenoid comb C Revert the control system to the pre Revert to the pre programmed value by keeping pressing cancel key and then start the machine P S The in...

Page 35: ...P32...

Page 36: ...P33...

Page 37: ...P34...

Page 38: ...P35...

Page 39: ...P36...

Page 40: ...P37...

Page 41: ...P38...

Page 42: ...P39...

Page 43: ...P40...

Page 44: ...P41...

Page 45: ...P42...

Page 46: ...P43...

Page 47: ...P44...

Page 48: ...The specification and or appearances of the equipment described in this instruction book parts list are subject to change because of modification which will without previous notice KZ508S 3 MAR 2021...

Reviews: