background image

EN

Other functions:

Automatic turn off:

After 4 hours of continuous working from the last 

setup, the appliance turns off and closes automa-

tically.

Grease filters saturation:

After  30  hours  of  working,  the  speed  indicators 

“D”

 will all flash simultaneously, signaling the gre-

ase filters saturation.

To reset this alarm, push the 

“TIMER”

 key when 

the downdraft is completely off and the extractable 

unit is closed.

Calibration SU-DD2-L:

The  cooker-hood  carries  out  its  self-calibration 

every 3 complete cycles of its extractable unit.

By  pushing  the 

“TIMER”

  key  6  times  consecuti-

vely (MAX break between one push and the other 

is 3 sec.) all the leds will flash and the calibration 

will be reset.

After the next 3 cycles the downdraft will carry out 

its self-calibration.

Calibration: SU-DD3

After  the  downdraft  has  been  installed,  the  aspi-

ration panel must be calibrated. This operation is 

necessary to regulate the power exstraction of the 

aspiration  panel.  Connect  the  product  to  the  po-

wer line, making sure that it is conformed to the 

supply voltage indicated on the technical data tag. 

Pushing the ON/1 button (Fig. 15H) the aspiration 

panel rises. After it has reached a height of 180mm 

from the cooketop, press OFF (Fig. 15G), to stop 

the extraction then the Timer and after 2 sec. the 

OFF button. The downdraft will carry out the cali-

bration of its aspiration panel rising and retracting 

for some centimeters.

During this phase, the buttons on the pushbutton 

control  panel  blink. At  the  end  of  the  calibration, 

the aspiration panel get back to the previous po-

sition  and  the  button  end  to  blink.  Wait  until  the 

aspiration panel stops moving before re-activating 

the extraction.

After the self-calibration stage, close the filter unit 

completely using the OFF button. 

Stand-by:

When the extractable unit is closed and the light 

is  switched  off,  the  control  panel,  after  6  secon-

ds, activates the Stand-by function, reducing the 

brightness of the leds.

This function can be stopped by pressing ON/ OFF 

or LIGHT key.

Security System:

If  there  is  an  obstacle  while  the  extractable  unit 

is closing, the Downdraft stops closing and rises 

again thanks to a security system.

11

SUDD2L - SUDD3

Summary of Contents for SU-DD2-L INOX

Page 1: ...ons INSTALLATION USE AND MAINTENANCE INSTRUCTION SU DD2 L TC SU DD2 L INOX SU DD3 TC BEFORE INSTALLATION ENSURE THERE IS NO VISIBLE OR HIDDEN DAMAGE SUSTAINED DURING SHIPPING SHIPPING DAMAGE MUST BE R...

Page 2: ......

Page 3: ...y use rigid smooth steel for ducting The exhaust point of the blower requires a 5 29 32 round connection if the downdraft it s con nected with SUM1 external motor or with motor on board and a 7 7 8 if...

Page 4: ...u will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product For more detailed information a...

Page 5: ...ALLING THE HOOD 7 Grease filter removal mounting the activated charcoal filter 8 Electrical connection of the hood 9 HOW THE COOKER HOOD WORKS 10 CLEANING THE HOOD 12 OPERATIONAL ANOMALIES 13 AFTER SA...

Page 6: ...DESCRIPTION OF THE APPLIANCE EN DESCRIPTION OFTHE APPLIANCE DESCRIPTION OFTHE APPLIANCE 16 S 002 L FLUSH TOP OFTHE APPLIANCE 16 S 002 L FLUSH TOP OFTHE APPLIANCE 6 SUDD2L SUDD3...

Page 7: ...ft inside the cabinet using the special fixing brackets supplied with the pro duct Fig 3 Insert the brackets in the lower side of the downdraft Fig 3 in such a way that there is a 2 mm distance betwee...

Page 8: ...ilters are required for this type of cooker hood Air recycled through the charcoal filters is recircu lated into the kitchen thanks to a duct conveying the air on one side of the cabinet Fig 11 CAUTIO...

Page 9: ...from all heat sources e g oven sides or cook top NOTA Electrical Supply This range hood requires a 120V 60 Hz supply and draws a maximum or 3 amps We decline any responsibility in case of acci dents c...

Page 10: ...n is signalled by the flashing LEDs D for the set speed The timer can be cancelled by press ing the key again MODEL SU DD3 VERSION OFF switch Fig 16G It is used to close the aspi ration panel complete...

Page 11: ...line making sure that it is conformed to the supply voltage indicated on the technical data tag Pushing the ON 1 button Fig 15H the aspiration panel rises After it has reached a height of 180mm from...

Page 12: ...saturation is signa led by the blinking of the 4 central leds To reset hold down the timer button for at least 3 seconds while the carriage is open In the recirculation mode the active charcoal filte...

Page 13: ...nd vapors present in the room The kitchen is ventilated well enough to allow air for intake The charcoal filter is not worn out filtering version cooker hood The air outlet channel is free and complia...

Page 14: ...us warrants to the original consumer purchaser of its products that such products will be free from defects in materials and workmanship for a period of three years from the original date of purchase...

Page 15: ...IMAGES 15 SUDD2L SUDD3...

Page 16: ...S DD2 L FLUSH TOP 66 2 mm 2 6 3 4 5 1 16 SUDD2L SUDD3...

Page 17: ...S DD2 L FLUSH TOP 67 9 8 7 10 11 12 17 SUDD2L SUDD3...

Page 18: ...S DD2 L FLUSH TOP 68 10 09 90002103999 N 220 240V 50 HZ ATTUATORE 12Vcc 68W MAX 68W TYPE FSEE EQUIPMENT S 002 EM_TC X22 Q3 X0 90002002001 A C B 13 14 14 15 18 SUDD2L SUDD3...

Page 19: ...19 SUDD2L SUDD3...

Page 20: ...90002020004 11 16...

Reviews: