EN
Other functions:
Automatic turn off:
After 4 hours of continuous working from the last
setup, the appliance turns off and closes automa-
tically.
Grease filters saturation:
After 30 hours of working, the speed indicators
“D”
will all flash simultaneously, signaling the gre-
ase filters saturation.
To reset this alarm, push the
“TIMER”
key when
the downdraft is completely off and the extractable
unit is closed.
Calibration SU-DD2-L:
The cooker-hood carries out its self-calibration
every 3 complete cycles of its extractable unit.
By pushing the
“TIMER”
key 6 times consecuti-
vely (MAX break between one push and the other
is 3 sec.) all the leds will flash and the calibration
will be reset.
After the next 3 cycles the downdraft will carry out
its self-calibration.
Calibration: SU-DD3
After the downdraft has been installed, the aspi-
ration panel must be calibrated. This operation is
necessary to regulate the power exstraction of the
aspiration panel. Connect the product to the po-
wer line, making sure that it is conformed to the
supply voltage indicated on the technical data tag.
Pushing the ON/1 button (Fig. 15H) the aspiration
panel rises. After it has reached a height of 180mm
from the cooketop, press OFF (Fig. 15G), to stop
the extraction then the Timer and after 2 sec. the
OFF button. The downdraft will carry out the cali-
bration of its aspiration panel rising and retracting
for some centimeters.
During this phase, the buttons on the pushbutton
control panel blink. At the end of the calibration,
the aspiration panel get back to the previous po-
sition and the button end to blink. Wait until the
aspiration panel stops moving before re-activating
the extraction.
After the self-calibration stage, close the filter unit
completely using the OFF button.
Stand-by:
When the extractable unit is closed and the light
is switched off, the control panel, after 6 secon-
ds, activates the Stand-by function, reducing the
brightness of the leds.
This function can be stopped by pressing ON/ OFF
or LIGHT key.
Security System:
If there is an obstacle while the extractable unit
is closing, the Downdraft stops closing and rises
again thanks to a security system.