background image

4

The symbol on the product or on its packaging indicates that this product 
may not be treated as house-hold waste. Instead it shall be handed 
over to the applicable collection point for the recycling of electrical and 
electronic equipment. By ensuring this product is disposed of correctly, 
you will help prevent potential negative consequences for the environment 
and human health, which could otherwise be caused by inappropriate 
waste handling of this product. For more detailed information about 
recycling of this product, please contact your local city office, your 
household waste disposal service or the shop where you purchased the 
product. This appliance is marked according to the European directive 
2002/96/EC on waste electrical and electronic equipment (WEEE).

Sirius warranty covers only Sirius product. If you choose to install a non-Sirius branded accessory 
such as flexible ducting, Sirius will only warrant the rangehood and motor. If installation is found to be 
the cause of failure or issue then charges will apply for service and parts. 

Flexible ducting is not permitted under any circumstances. Flexible ducting has been found to 
increase noise levels, increase vibration and reduce airflow. Sirius Semi-rigid or solid ducting can be 
used in lieu. There is a range available to suit any application.

Ducting available at www.siriusbrand.com

6 Year Warranty when Sirius Ducting is used. Full replacement warranty on parts and labour.

See website for terms & conditions.

A reduction in the duct diameter from stated ducting size will void warranty.

If you are in doubt about the ducting, please contact Sirius on 1300 762 219 prior to installation

WARNING

The appliance must be installed and 

connected to the power supply only by a 

qualified technician.

•  There should be adequate ventilation of the room when the rangehood is used at the same time as 

appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the 
room)

•  The details concerning the method and frequency of cleaning
•  There is a fire risk if cleaning is not carried out in accordance with the instructions;
•  Do not flambé under the range hood;
•  CAUTION: Accessible parts may become hot when used with cooking appliances.

BEFORE YOU INSTALL - DUCTING INFORMATION

Summary of Contents for 9351116001353

Page 1: ...The Kite and The Line Rangehoods INSTALLATION AND USE INSTRUCTIONS The Kite SLT977EMEL EAN 9351116003050 The Line SLT978EMELBK EAN 9351116001353 Congratulations on your purchase Thank you for choosing...

Page 2: ...2...

Page 3: ...EASUREMENTS INSTALLING THE TIMBER SUPPORT BEAMS MOTOR AND VENTING OPTIONS TOP VENT INSTALLATION SIDE VENT INSTALLATION SEM11 SEM 21 DUCTING FROM MOTOR TO WALL ELECTRICAL CONNECTION REMOTE CONTROL OPER...

Page 4: ...service and parts Flexible ducting is not permitted under any circumstances Flexible ducting has been found to increase noise levels increase vibration and reduce airflow Sirius Semi rigid or solid du...

Page 5: ...before carrying out cleaning or maintenance operations Adequately ventilate the room when a rangehood and other appliances powered by energy other than electricity are used simultaneously so that the...

Page 6: ...stallation must comply with the regulations in force regarding the ventilation of enclosed environments In particular discharged air must not be conveyed into a duct used for fumes discharge or discha...

Page 7: ...te was purchased from Reduction of the ducting diameter will void the manufacturer warranty as it will severely affect the performance of the motor and may cause damage with prolonged usage Use ductin...

Page 8: ...damage to the unit when it is first turned on Step 1d After feeding the cables through the rangehood using the four supplied grub screws fix the light into place by allowing the cables to pass throug...

Page 9: ...cassettes are held in place with the use of the 4 x 250mm threaded bolts Using the measurements in the Fig 7 line drawings ensure that there is timber framework not supplied inside the cavity to suppo...

Page 10: ...ass the 4 x 250mm bolts through them ensuring that the larger washer is on the INSIDE OF THE CEILING CASSETTE Fig 8a Lift the cassette into position and ensure that the 4 x 250mm bolts pass through th...

Page 11: ...otor MUST be accessible for servicing at all times NOTE Note Roof vent option shown Motor can also be wall or eave vented Motor can be a maximum 2 metres from ground level For SEM51 installation pleas...

Page 12: ...art D PART D PART D PART E PART A PART A PART D PART D PART E PART E SEM21 OUTSIDE INSIDE WALL INTERNAL MOTOR Ducting to SEM11 150mm Please note that the final exit point for SEM11 can be through the...

Page 13: ...or plate Part A 2A Connect the length of ductwork Part E directly to Part A then secure with a universal ring clamp Part D 3A Secure to the motor with a universal ring clamp Part D SEM21 MOTOR SEM11 M...

Page 14: ...available please head to www siriusbrand com or contact your retailer The location of the motor is to be no less than 2 metres away from the rangehoood Failure to do so may result in additional noise...

Page 15: ...OTOR 1 Remove the four screws holding the front of the housing in place to expose the connections 2 Following the wiring chart on the fron of the housing connect each wire to the matching colour makin...

Page 16: ...els only This function provides for lights dimmability ranging from 20 to 100 by continuously pressing the Light ON OFF on the remote control Functions are the following Light ON or OFF shortly press...

Page 17: ...the new transmission code Once the transmission code is changed in the radio control unit the electronic central unit of the cooker hood must be made to set the new code in the following way Press th...

Page 18: ...or by using Touch ID or Face ID The steps below don t apply to the iPhone 5c iPhone 5 iPhone 4s or the iPhone 4 1 Open the App Store To install apps you must sign in with your Apple ID or create one...

Page 19: ...or Archive folder If you didn t find yet please create another account 5 From Login page Insert the e mail and password of your account and tap LOGIN Fast way using the WPS procedure if your router h...

Page 20: ...you remove the grease filters 8 Press ACTIVATE DEVICE and you have a pop up message 8 Tap the device icon Enjoy your device 5 On your range hood Switch off completely light and motor Hold button for 3...

Page 21: ...NGS 4 ON YOUR RANGE HOOD Switch off completely light and motor Hold button for 3 secs for settings menu LEDs will flash press button to enable manual pairing Hold button for 3 sec button to save Note...

Page 22: ...22 6 Connect to HOOD network inserting as passwork password 7 TURN BACK 8 ENTER WI FI NAME AND WI FI PASSWORD 9 TAP CONFIGURE 10 IN CASE OF FOLLOWING ERROR Go back to the home page TAP Claim Devices...

Page 23: ...uct visible by removing the grease filters 12 Connect your mobile to your home Wi Fi Router network 13 Press ACTIVATE DEVICE and you have a pop up message 14 Tap the device icon Enjoy your device REMO...

Page 24: ...ing OFF BI POWER The BI POWER function allows reducing the performance of the fan if the maximum efficiency of the product is not required LIGHT Slide the toggle switch for switching ON OFF Slide the...

Page 25: ...25 RENAME DEVICE Tap on and rename device SHARE DEVICE Tap on and share device only to subscribed account...

Page 26: ...26 PART A PART B PART C 150mm adaptor plate 10mm Adaptor mounting screws Threaded support bars PARTS LIST INCLUDED...

Page 27: ...27 PART D Universal ring clamp URC25 215 325 OPTIONAL PARTS LIST PART E Semi rigid aluminium ducting 150mm SRPRO 30 150...

Page 28: ...28 WIRING DIAGRAM SLT977EMEL SLT978EMEL...

Page 29: ...Sirius s Total Peace of Mind Protection Plan Australian New Zealand 3 6 Year Protection Plan This guarantees your appliance for a full 3 years parts and labour 10 years for the off board motors coveri...

Page 30: ...nty will not apply where a The fault is caused by accident misuse an infestation of insect and or vermin fire flood or the use of products not approved by Arisit Pty Limited b There has been a failure...

Reviews: