background image

5

Min. 1200mm - Max. 1600mm distance 

for 

barbecues.
If the rangehood is positioned above the max height 
recommended, warranty may be compromised 
as performance of the rangehood will be affected.
Measurement is taken from the top of the grills to the 
underside of the hood. (Fig.1)

•  The air being drawn can’t be conveyed through 

or into a duct used to let out fumes from 
appliances fed by energy other than electric 
power (eg. centralized heating, radiators, water 
heaters, etc.).

•  Attention: remove any possible PVC film from the 

stainless steel, including the filters.

•  To externally vent, please comply with the 

pertaining rules given by competent authorities.

•  Provide the room with an adequate ventilation 

when a rangehood and appliances fed by energy 
other than electric power (gas, oil, or coal stoves, 
etc.) are used simultaneously. The rangehood, 
when evacuating the air, could generate a 
negative pressure in the room which can’t exceed 
the limit of 0.04 mbar, in order to avoid the 
suck of exhausts deriving from the heat source. 
Therefore the room should be provided with air 
intakes to allow a constant flow of fresh air.

If the rating label in the rangehood shows the symbol       
    , the appliance is built in class II° and it 

does not 

need

 any earth connection.

If the rating label in the rangehood does not show 
the symbol     , the appliance is built in class I° and it 

needs

 the earth connection.

When performing the electrical connections on the 
appliance, please make sure that the current-tap 
is provided with earth connection and that voltage 
values correspond to those indicated on the label 
placed inside the appliance itself. 

Before carrying out any cleaning or maintaining 
operations, the appliance needs to be switched off. 
If the appliance is not provided with a non-separable 

When ducting rangehood, options are as follows:

Roof vent - EASYROOF 200T/M

*Kit includes roof flashing

Download installation guide

Eave vent - EASYEAVE 200

Download installation guide

Wall vent - EASYWALL 200

Download installation guide

flexible cable and plug, or with another device 
ensuring omnipolar disconnections from the grid, 
with an opening distance between the contacts of at 
least 3mm, then such disconnecting devices must be 
supplied within the fixed installation.
If the fixed appliance is endowed with a supply cord 
and a plug, the appliance has to be put in a place 
where the plug can be reached easily.

The use of materials which can burst into flames 
should be avoided in close proximity of the appliance. 
When frying, please pay particular attention to fire 
risk due to oil grease. Being highly flammable, fried 
oil is especially dangerous. Do not use uncovered 
electric grills. In order to avoid possible fire risk, all 
instructions for grease-filter cleaning and for removing 
eventual grease deposits should be strictly followed.

WARNING

Min. 1200 - Max. 1600

(Fig. 1)

(Fig. 2a)

(Fig. 2b)

(Fig. 2c)

Dome 
featured on 
200mm kit 
only

FRONT VIEW

Summary of Contents for 9351116000950

Page 1: ...OD ONBOARD INSTALLATION INSTRUCTIONS Congratulations on your purchase Thank you for choosing a Sirius product SL80FRESCO900 EAN 9351116000950 SL80BBQ1200M EAN 9351116001032 SL80BBQ1200B EAN 9351116002...

Page 2: ...2...

Page 3: ...3 BEFORE YOU INSTALL INSTALLING THE RANGEHOOD OPERATION MAINTENANCE SL80 WIRING DIAGRAM BRACKET TEMPLATE WARRANTY 4 6 8 8 9 10 11...

Page 4: ...service and parts Flexible ducting is not permitted under any circumstances Flexible ducting has been found to increase noise levels increase vibration and reduce airflow Sirius Semi rigid or solid du...

Page 5: ...s the earth connection When performing the electrical connections on the appliance please make sure that the current tap is provided with earth connection and that voltage values correspond to those i...

Page 6: ...alling the appliance in order not to damage the appliance itself the metal grease filter should be removed These filters could be removed by pushing the handles towards the back side of the rangehood...

Page 7: ...ring clamp if you are using semi rigid ducting If you are using solid rigid ducting an external duct connector is required Note do not fix the ducting in place with screws as they will prevent the mo...

Page 8: ...ast depending on its use Filters may require cleaning sooner if frequent heavy cooking is done To clean the appliance itself water and detergent are recommended while abrasive products should be avoid...

Page 9: ...9 SL80 WIRING DIAGRAM...

Page 10: ...10 BRACKET TEMPLATE...

Page 11: ...Sirius s Total Peace of Mind Protection Plan Australian New Zealand 3 6 Year Protection Plan This guarantees your appliance for a full 3 years parts and labour 10 years for the off board motors coveri...

Page 12: ...arranty will not apply where a The fault is caused by accident misuse an infestation of insect and or vermin fire flood or the use of products not approved by Arisit Pty Limited b There has been a fai...