background image

TI03-285ENG-REV13

5 of 8

• 

The projector lens and filter slides should be cleaned 

with a lens cloth or lens paper ONLY.  Paper prod-

ucts and other cleaning materials will damage the 

surfaces.

Replacing the Batteries:  

• 

The batteries are rated for over 300 charging cycles.  

When the battery charge lasts less than 30 minutes, 

the batteries should be replaced.

•  Replacement batteries should be ordered through 

SIRCHIE, No. FAL309 2-6V DC sealed lead acid 

8Ah.

• 

Remove the batteries from the battery case.

• 

Remove the cords from the battery terminals (Fig. 3).

• 

Remove the connection cable from between the batteries.

• 

Place the connection cable on the new batteries.

• 

Install the cords, being careful to connect the positive cord to the positive terminal as marked.

• 

Place batteries back into case.

TROUBLESHOOTING

• 

If the unit fails, the battery, fuse, or lamp may be at fault. To troubleshoot, first make sure the battery is fully 

charged.

• 

If the battery is fully charged, follow the instructions below to check the fuse. If necessary, replace the fuse.

• 

If the fuse is OK, replace the lamp as directed below.

• 

If these steps do not fix the unit, return for repair.

FIGURE 3—Battery terminal locations.

Summary of Contents for FAL3000

Page 1: ...ument may be hand held in two different positions or mounted on a standard photographic type tripod Battery operation permits searching a multitude of surfaces even when working in the tightest situat...

Page 2: ...ead all cautionary labels on the battery charger before using Warning To reduce risk of injury chargers should only be used to charge SIRCHIE battery packs The charger may damage or cause other types...

Page 3: ...t damaging the battery Operation 1 Attach the handle by lifting one of the two locking slides and placing in either the handle or pistol position 2 Select the Sliding Filter Array to be used and inser...

Page 4: ...Orange Orange Cyanoacrylate stained with Rhodamine G 470nm 505nm Orange Red Orange Trace evidence on blue green background 530nm Orange Red Red General crime scene search White NONE NONE Tripod Use T...

Page 5: ...ery case Remove the cords from the battery terminals Fig 3 Remove the connection cable from between the batteries Place the connection cable on the new batteries Install the cords being careful to con...

Page 6: ...and carefully unplug the lamp power connector Fig 6 Set the expired lamp aside 5 Unpack the new lamp assembly and plug it into the lamp connector CAUTION Do Not touch lamp as this will significantly r...

Page 7: ...NG REV13 7 of 8 EXCITATION FILTER SPECTRAL CHARACTERISTICS Approximate wavelengths of excitation filters depicted in nanometers nm 415nm FILTER 365nm FILTER 470nm FILTER 450nm FILTER 530nm FILTER 505n...

Page 8: ...Color temp 4200O K Lamp Output 3200 lumens Dimensions 14 75 x 5 x 5 without handle 375mm x 127mm x 127mm Weight w battery filter 3 74 lbs 1 72kg Cooling 12V DC 11CFM quiet running fan No 022 0139 Batt...

Reviews: