The FAL3000 should be used to examine the crime scene, rotating through the various filters for the different
types of evidence.
TABLE I: Choosing the correct light for various types of evidence
USAGE CHART
Evidence Type or Use
Light to Use
Goggles
Camera Filter
Bodily fluids, semen
365nm
UV, yellow, orange
NONE
Bone fragments
365nm
UV, orange
NONE, orange
Latent fingerprints in oils, grease
450nm
Yellow
Yellow
Fluorescent powders (most)
415nm, 450nm
Yellow, Orange
Orange
DFO treated latent prints
450, 470nm
Orange, Red
Orange
Cyanoacrylate stained with Basic Yellow
450nm, 470nm
Yellow, Orange
Orange
Cyanoacrylate stained with Rhodamine G
470nm, 505nm
Orange, Red
Orange
Trace evidence on blue/green background
530nm
Orange, Red
Red
General crime scene search
White
NONE
NONE
Tripod Use
The operator is afforded hands-free operation with the professional duty included. The lamp assembly is
equipped with a 1/4-20 threaded mounting socket and the tripod features a removable mounting coupler.
MAINTENANCE
No field repairs to the instrument or battery charger are recommended. If the instrument will not function and you
have determined that the batteries are fully charged, and that the lamp has been replaced, please contact Customer
Service at 800-356-7311 for a return authorization.
General:
•
The outside of the unit can be cleaned with a mild detergent and water. Do not immerse in any liquid.