The plug must NOT be used if the cover is omitted 

or lost until a replacement is obtained.

 -  Make certain that only the correct fuse cover is 

used and fitted. 

- For plugs with detachable fuse cover the 

replacement must be the same as the colour 

insert in the base of the plug, or as directed by the 

embossed wording on the base of the plug.

 -  If the detachable fuse cover is lost a replacement 

may be purchased from a Service Centre.

PUT INTO SERVICE / STARTING 

UP

  

See fig. 

A

- Connect the high pressure hose to the trigger gun.

- Push the high pressure hose into the trigger gun.

Note: Make sure the connection nipple is aligned 

correctly.

- Check the secure connection by pulling on the 

high pressure hose.

See fig. 

B

- Insert the high pressure hose tightly into the quick 

coupling on the appliance

See fig. 

C

- Screw the coupling element to the water 

connection on the appliance.

-   Attach the water supply hose to the coupling on 

the water connection.

 NOTE:  The supply hose is not included.

-  Connect the water supply hose to the water 

supply.

-  Completely open the water tap.

-   Insert the mains plug into the socket.

-   Turn on the appliance “I/ON”.

See fig. 

D

-   Unlock the lever on the trigger gun.

-   Pull on the lever of the trigger gun; the device will 

switch on.

-   Switch the appliance on for a (max. of 1 minute) 

and wait until the water exits at the hand spray 

gun without bubbles.

-   Release the lever on the trigger gun.

 NOTE:  Release the lever of the trigger gun; the 

device will switch off again.

-   High pressure remains in the system.

See fig. 

E

-   Lock the lever on the trigger gun.

Operation

See fig. 

F

- Push the spray lance into the trigger gun and fasten 

it by turning it through 90°.

-   Unlock the lever on the trigger gun.

See fig. 

G

-   Pull on the lever of the trigger gun; the device will 

switch on.

 14WARNING: Appliance with fluid under pres-

sure. Keep a firm hold on the gun and be prepared 

to take the kickback pressure.

See fig.

H

>  HIGH PRESSURE LANCE

See fig.

I

>  DETERGENT SUCTION

  

See fig.

L

>  HIGH PRESSURE HOSE

Use the hydrocleaner only if the hose is completely 

uncoiled and extended. 

See fig. 

M

>  SWITCHING OFF

T.S.  Total Stop  

  

( if fitted)

 NOTE: Total Stop, which stops the machine 

during the bypass phase. To start the water 

cleaner, it is therefore necessary to set the switch 

on position (I)“ON”; after that press the pistol 

trigger: the Total Stop  will start the machine 

and will stop it automatically when the trigger is 

released. It is advisable to put on the safety of the 

pistol trigger whenever the machine is stopped, 

in order to avoid unintentional starting.

- Any automatic start of the machine without 

pressing the gun trigger is attributable to air 

bubbles in the water or other similar phenomena 

which do not imply the existence of any defects in 

the machine. 

-  Do not leave the appliance unattended during 

the standby for more than 5 minutes. Contrarily, 

for the safety of the appliance it is necessary to 

re-turn the switch into the (0) OFF position.

Summary of Contents for 08970

Page 1: ...Technical data plate HIGH PRESSURE CLEANER WARNING read the instructions carefully before use SIP CW2000...

Page 2: ...4 Water outlet 5 High pressure hose 6 Gun 7 Lance 8a Nozzle 8b Turbo nozzle 8c Detergent nozzle 9 Electric cable 10 Water inlet filter Quick hose fitting DESCRIPTION OFTHE MACHINE 2 1 10 6 7 5 8a 8b...

Page 3: ...6 7 click click click click X2 ASSEMBLY INSTRUCTIONS Depending on the model there are differences in the scopes of delivery 3...

Page 4: ...A B C D Optional IN OUT 1 4 2 3 ON I 5 2 5 40 C Optional 1 2 inch 13 mm CLICK 15 30 45 60 1 IN 1 min click 4...

Page 5: ...E G F 1 2 3 click click 5...

Page 6: ...Click Click D 6 spread pattern pencil jet H turbo lance 2 1 Optional I CLICK 4C 3C...

Page 7: ...Use the hydrocleaner only if the hose is completely uncoiled and extended 7 L OFF 1 2 3 4 M 1 2 3 L Optional N OFF 1 2 3 4 M 4 OPTIONAL OPTIONAL HIGH PRESSURE HOSE...

Page 8: ...e cleaned from a minimum distance of 30 cm otherwise the vehicle tyre tyre valve could be damaged by the high pressure jet The first indication of this is a discoloration of the tyre Damaged vehicle t...

Page 9: ...k of explosion Do not spray flammable liquids 22WARNING To ensure machine safety use only original spare parts from the manufacturer or ap proved by the manufacturer 23WARNING Do not direct the jet ag...

Page 10: ...ble type by professionally qualified staff Never use the appliance in ambient temperatures below 0 C if it is equipped with a PVC H VV F cable XY WARNING Inadequate extension cords can be dangerous XJ...

Page 11: ...ease the lever on the trigger gun NOTE Release the lever of the trigger gun the device will switch off again High pressure remains in the system See fig E Lock the lever on the trigger gun Operation S...

Page 12: ...t pipes to the pump for leaks or blockage Strong pressure fluctuations Clean the high pressure nozzle Remove dirt from the nozzle hole with a needle and then rinse out with water from the front Pump l...

Page 13: ...ch as Gaskets diaphragms sealing rings oil and so on The Manufacturer shall not be held re sponsible for accidents to the operator or third parties while the equipment is in use This warranty shall no...

Page 14: ...W 02 2019 7 700 0535 00 EN60335 1 EN60335 2 79 EN62233 2008 EN50581 EN55014 1 2006 A1 2009 A2 2011 EN55014 2 2015 EN 61000 3 3 2014 EN61000 3 3 2013 2006 42 EC Machinery Directive 2009 127 EC EMC Dire...

Page 15: ...1 2009 A2 2011 BSEN50581 BSEN62233 2008 BSEN60335 2 79 BSEN60335 1 Electromagnetic Compatibility Regulations 2016 Noise Emission in the Environment by Equipment for use Outdoors Regulations 2001 The R...

Page 16: ...cod 7 100 2261 02 07 2021 16...