Ensure that the pump is connected to the correct supply voltage.  
Become familiar with the controls before operating this pump.  
Do not attempt to move the pump when it is loaded and/or in operation.  
Check all bolts, nuts, pipe fittings and screws etc. before each use. 
When  maintaining  this  pump,  only  the  manufacturer’s  original  replacement 

parts may be used. 
Do not operate the pump with wet hands. 
Ensure  that  the  operator  has  read  and  understands  the  material  safety  data 

sheet (MSDS) for the type of fuel being pumped  and that all cautions are ad-

hered to. 
Always operate the pump in a well ventilated area to reduce fume build up. 
Ensure that the battery is as far away as possible from the pump when connect-

ing the power supply leads. 
Do not turn the pump on / off by connecting / disconnecting the supply leads; 

Always use the switch on the pump. 
Ensure that the switch is in the off position before connecting the power supply 

leads. 
Never operate the pump for longer than its  duty cycle (30 minutes); Allow the 

pump to cool for 30 minutes if the pump has been run for the length of its duty 

cycle. 
Never smoke whilst operating the pump. 
Never place the pump where open flames are present. 
Never operate the pump ‘dry’ with no fuel running through it; This will damage 

the internal components of the pump and invalidate your warranty. 
Never operate the pump for more than 2-3 minutes in ‘by-pass’ mode (with the 

supply nozzle closed). 
Appropriate personal protective equipment, clothing, gloves and safety glasses 

etc. 

must

 be worn and 

must

 be de-signed to protect against all hazards creat-

ed.  Severe  permanent  injury  can  result  from  using  inappropriate  or  insufficient 

protective equipment.  

Always wear suitable eye protection when using or maintaining the 

transfer pump. 

19 

  NOTES 

Summary of Contents for 06801

Page 1: ...e packaging to the local amenity tip and place into the appropriate recycling bin Never dispose of electrical equipment or batteries in with your domestic waste If your supplier offers a disposal faci...

Page 2: ...e 12v Diesel Transfer pump SIP Part No 06801 24v Diesel Transfer Pump SIP Part No 06803 Conforms to the requirements of the following directive s as indicated 2004 108 EC EMC Directive 2008 35 EC RoHS...

Page 3: ...This Manual 4 Safety Instructions 9 Electrical Connection 10 Guarantee 11 Contents and Accessories 12 Technical Specification 13 Assembly Instructions 17 Operating Instructions 19 Maintenance 20 Wirin...

Page 4: ...ilt in bypass valve for added safety and the motor has a 30 minute duty cycle If you are unsure of its relative applications do not hesitate to contact us and we will be more than happy to advise you...

Page 5: ...ay affect its op eration should be correctly repaired or replaced by an authorised service centre un less otherwise indicated in this instruction manual KEEP ALL COVERS PANELS IN PLACE Never operate t...

Page 6: ...necting disconnecting the supply leads Always use the switch on the pump Ensure that the switch is in the off position before connecting the power supply leads Never operate the pump for longer than i...

Page 7: ...tation speed Check electrical connections and battery Motor surface tempera ture gets hotter than 100 C 212 F Fluid is too thick Fluid must not be thicker than diesel fuel Duty cycle exceeded The pump...

Page 8: ...ENTS AND ACCESSORIES Note If any of the above are missing or damaged contact your distributor immediately 1 2 3 4 5 6 1 Diesel Transfer Pump 2 Delivery Gun Pistol 3 Power Supply Lead connected to pump...

Page 9: ...v DC Motor 140 watts 140 watts Duty Cycle 30 mins max 30 mins max Flow Rate 40 l min max 40 l min max Protection IP55 IP55 Net Weight TECHNICAL SPECIFICATION F G H Ref Description Ref Description A Po...

Page 10: ...the pump inlet and tighten to secure Fit the inlet filter to the opposite end of the hose and tighten to secure Fig 3 O Ring Hose Fig 1 Pump Outlet Pump Inlet Fig 2 15 PARTS LIST 06801 Ref No Descript...

Page 11: ...nput leads as described on page 7 Insert the delivery nozzle into the container to be filled Switch the motor on Operate the nozzle lever to dispense fluid The pump can be installed in any direction P...

Page 12: ...ly Clean the metal mouth portion of the battery clips with steel wool monthly to maintain good electrical connection to the battery Check the power cables and clips for any damage before each use repa...