  OPERATING INSTRUCTIONS….cont 

Caution: 

Never  run  the  pump  in  bypass  mode  (with  the  delivery  nozzle 

closed) for more than 1 minute. 

When  the  desired  amount  of  fluid  has  been  dispensed,  release  nozzle  lever  to  stop 

flow.  

Immediately switch motor off.  

Caution: 

Never  run  the  pump  for  more  than  30  minutes  maximum,  and 

allow the pump to cool for at least 30 minutes. 

13 

  MAINTENANCE 

Other than keeping the pump clean, there is very little maintenance required. 

 

Inspect and clean the inlet filter on the inlet hose at least monthly.  
Clean the metal “mouth” portion of the battery clips with steel wool monthly to 

maintain good electrical connection to the battery.  
Check the power cables and clips for any damage before each use; repair or 

replace as necessary. 
Hoses  and  fittings  should  be  inspected  before  each  use  and  replaced  /  re-

paired if cracked / worn or leaking.  
Rotor and vanes will eventually wear, and should be replaced if pump perfor-

mance  degrades.  See  the  “Operational  Problems”  section  to  determine  if  re-

placement is needed.  
Drain hoses and pump and store in a clean, dry place when not in use.  

Caution: 

Ensure  that  the  pump  is  turned  off  and  that  the  clips  are  re-

moved from the power supply before carrying out any cleaning or mainte-

nance. 

Summary of Contents for 06801

Page 1: ...e packaging to the local amenity tip and place into the appropriate recycling bin Never dispose of electrical equipment or batteries in with your domestic waste If your supplier offers a disposal faci...

Page 2: ...e 12v Diesel Transfer pump SIP Part No 06801 24v Diesel Transfer Pump SIP Part No 06803 Conforms to the requirements of the following directive s as indicated 2004 108 EC EMC Directive 2008 35 EC RoHS...

Page 3: ...This Manual 4 Safety Instructions 9 Electrical Connection 10 Guarantee 11 Contents and Accessories 12 Technical Specification 13 Assembly Instructions 17 Operating Instructions 19 Maintenance 20 Wirin...

Page 4: ...ilt in bypass valve for added safety and the motor has a 30 minute duty cycle If you are unsure of its relative applications do not hesitate to contact us and we will be more than happy to advise you...

Page 5: ...ay affect its op eration should be correctly repaired or replaced by an authorised service centre un less otherwise indicated in this instruction manual KEEP ALL COVERS PANELS IN PLACE Never operate t...

Page 6: ...necting disconnecting the supply leads Always use the switch on the pump Ensure that the switch is in the off position before connecting the power supply leads Never operate the pump for longer than i...

Page 7: ...tation speed Check electrical connections and battery Motor surface tempera ture gets hotter than 100 C 212 F Fluid is too thick Fluid must not be thicker than diesel fuel Duty cycle exceeded The pump...

Page 8: ...ENTS AND ACCESSORIES Note If any of the above are missing or damaged contact your distributor immediately 1 2 3 4 5 6 1 Diesel Transfer Pump 2 Delivery Gun Pistol 3 Power Supply Lead connected to pump...

Page 9: ...v DC Motor 140 watts 140 watts Duty Cycle 30 mins max 30 mins max Flow Rate 40 l min max 40 l min max Protection IP55 IP55 Net Weight TECHNICAL SPECIFICATION F G H Ref Description Ref Description A Po...

Page 10: ...the pump inlet and tighten to secure Fit the inlet filter to the opposite end of the hose and tighten to secure Fig 3 O Ring Hose Fig 1 Pump Outlet Pump Inlet Fig 2 15 PARTS LIST 06801 Ref No Descript...

Page 11: ...nput leads as described on page 7 Insert the delivery nozzle into the container to be filled Switch the motor on Operate the nozzle lever to dispense fluid The pump can be installed in any direction P...

Page 12: ...ly Clean the metal mouth portion of the battery clips with steel wool monthly to maintain good electrical connection to the battery Check the power cables and clips for any damage before each use repa...

Reviews: