12
OPERATING INSTRUCTIONS….cont
Caution:
Never run the pump in bypass mode (with the delivery nozzle
closed) for more than 1 minute.
When the desired amount of fluid has been dispensed, release nozzle lever to stop
flow.
Immediately switch motor off.
Caution:
Never run the pump for more than 30 minutes maximum, and
allow the pump to cool for at least 30 minutes.
13
MAINTENANCE
Other than keeping the pump clean, there is very little maintenance required.
Inspect and clean the inlet filter on the inlet hose at least monthly.
Clean the metal “mouth” portion of the battery clips with steel wool monthly to
maintain good electrical connection to the battery.
Check the power cables and clips for any damage before each use; repair or
replace as necessary.
Hoses and fittings should be inspected before each use and replaced / re-
paired if cracked / worn or leaking.
Rotor and vanes will eventually wear, and should be replaced if pump perfor-
mance degrades. See the “Operational Problems” section to determine if re-
placement is needed.
Drain hoses and pump and store in a clean, dry place when not in use.
Caution:
Ensure that the pump is turned off and that the clips are re-
moved from the power supply before carrying out any cleaning or mainte-
nance.