MANUAL HEAD GATE- SET UP
Before operating Head Gate, verify the following:
The two wire ties securing
the handle of Head Gate to
the rod has been removed
and handle locked back
into place. Also, remove
the manual wrapped
around the cylinder.
Remove shipping plug
and install provided
breather plug into the top
chamber of the cylinder.
If breather is already
installed, disregard and
proceed to next step.
Before operation of head gate, cycle the head gate at least 10 times, ensuring to stop for 5 seconds
between opening and closing AND each cycle. Then with the head gate closed, manually attempt to open
the head gate doors. The opening at the top of the doors should never exceed ¾”.
Manual
Wire
Ties
Remove Shipping Plug and
replace with breather vent.