36
Function
Code
Default
Property
Setting
Range
0x000
○
○
0
0.50s
0.50s
○
○
○
0x00
1
◎
0
○
○
50.0%
○
0
1: Valid in running
,
clear
after
stop
2: Valid in running, clear
after
receiving the stop commands
0: invalid
1~100: The bigger the coefficient,
the
stronger the
braking is.
0.01~50.00s
0.01~50.00s
Group F08 PID Control
-
100.0~100.0%
0: Analog channel AI1 feedback
1: Reserve
2: High
-
speed
pulse
HDI feedback
3: MODBUS communication
feedback
0: 3-phase modulation
1: 2/3 -phase modulation switchover
0x00~0x011
LED ones: Action selection
when power off
0: Save when power off
1: Clear when power off
LED tens: Action selection when
MODBUS set frequency power off
0: Save when power off
1: Clear when power off
0: Keypad
digital reference(F08.01)
1: Analog channel AI1 reference
2: Reserve
3: High
-
speed
pulse
HDI setting
4: MS
reference
5: MODBUS
communication
setting
Name
F07.24
UP/DOWN
terminal control
setting
Magnetic flux
braking
F07.28
F07.25
F07.26
Up terminal
frequency
changing ratio
DOWN terminal
frequency
changing ratio
Frequency setting
at power loss
F07.27
F07.29
PWM modulation
mode
F08.00
PID
reference
source
selection
Keypad preset
PID reference
F08.01
F08.02
PID
feedback
source
selection
0: PID output is positive
1: PID output is negative
○
PID output
feature selection
Proportional gain
(Kp 1)
F08.03
F08.04
○
0.00~100.00
0
0.50
Function Parameters Table