29
Function
Code
Name
Default
Property
Setting
Range
○
○
Group F05
Output Terminals
●
F04.33
AI1
time
input filter
0.000~10.000s
0.100s
F04.34
Keypad analog
filter time
0.000~10.000s
0.050s
0
0
0: Invalid
1: Running
2: Forward
running
3: Reverse
running
4: Jog
running
5: AC drive
fault
6: Frequency level detection
FDT1
7: Frequency
level
detection
FDT2
8: Frequency reached
9: Zero
-
speed
running
10: Upper
limit
frequency
reached
11: Lower limit
frequency
reached
12: Ready
for
running
13: Reserve
14: Reserve
15: Reserve
16: Completion of simple PLC stage
17: Completion of simple PLC cycle
18:Setup
count
value
arrival
19: Designated
count
value
reached
20: External fault is valid
21: Length reached
22: Running
time
reached
23: MODBUS
communication
virtual terminal output
24: Torque arrival
F05.00
Reserve
●
0
Reserve
F05.04
○
1
Relay RO output
selection
F05.03
●
0
F05.02
Reserve
○
1
F05.01
Y output
selection
0x0
0.000s
0.000s
0.000s
○
○
○
○
0x0
~
0x3
0.000~50.000s
0.000~50.000s
0.000~50.000s
Polarity of
output terminals
Bit3 Bit2 Bit1 Bit0
0 0 R0 Y
Y switch-on delay
time
Y switch-off delay
time
Relay RO switch-
on delay time
F05.05
F05.06
F05.07
F05.08
Function Parameters Table